Encoders
Encoders
-
Absolute multiturn encoder as 24 bit version
- Direct output of the values via CANopen interface
- Battery-free multiturn technology
- High shock and vibration resistance thanks to magnetic sensing principle
- Flattened shaft for the safe installation of shaft couplings
Absolute multiturn encoder with hollow shaft RMA300
Absolute multiturn encoder with solid shaft RMB300
Absolute multiturn encoder with hollow shaft RMO300
Absolute multiturn encoder with solid shaft RMU300
Absolute multiturn encoder with solid shaft RMV300
Absolute multiturn encoder with solid shaft RM900S
Absolute multiturn encoder with solid shaft RM901S
Absolute multiturn encoder with solid shaft RM902S
Absolute multiturn encoder with solid shaft RM903S
Absolute multiturn encoder with solid shaft RM9000
Absolute multiturn encoder with solid shaft RM9001
Absolute multiturn encoder with solid shaft RM8004
Absolute multiturn encoder with solid shaft RM9010
Absolute multiturn encoder with solid shaft RM7011
Absolute multiturn encoder with solid shaft RM7012
Absolute singleturn encoder with solid shaft RN7012
Absolute multiturn encoder with solid shaft RM8007
Absolute multiturn encoder with solid shaft RM9003
Absolute multiturn encoder with solid shaft RM9004
Absolute multiturn encoder with solid shaft RM9006
Absolute multiturn encoder with solid shaft RM9007
Absolute multiturn encoder with hollow shaft RMA310
Absolute multiturn encoder with solid shaft RMB310
Absolute multiturn encoder with solid shaft RMB320
Absolute encoders for mobile machines
Absolute encoders detect position, angle, speed and distance with a resolution of up to 25 bits.
Multiturn encoders which do not require any batteries, however, do not only detect absolute angular positions but also count revolutions. Even in case of a power failure, the encoder continues to reliably detect the shaft position. The signals are output via the fieldbus interface CANopen. The flattened solid shaft ensures secure fixing of shaft couplings. Hollow-shaft encoders in a very small design, however, can be mounted without coupling. The protection rating IP69K provides reliable protection against ingress of water.
The singleturn encoders of the RN series on the other hand divide a mechanical revolution into a certain number of measuring steps. The measuring values are repeated after one complete revolution.
-------------------------------------