Fail-safe inductive sensors

Liên hệ Còn hàng

    Fail-safe inductive sensors

    • Certification to IEC 60947-5-3, ISO 13849-1 and IEC 61508

    • Ensuring operator and machine safety
    • No special actuator for electronic fail-safe sensors required
    • Connection of the sensors to safety plc or safe AS-i module

     

    Fail-safe inductive sensor GI855S

    Fail-safe inductive sensor GI854S

    Fail-safe inductive sensor GG855S

    Fail-safe inductive sensor GF761S

    Fail-safe inductive sensor GF762S

    Fail-safe inductive sensor GG761S

    Fail-safe inductive sensor GG762S

    Fail-safe inductive sensor GG854S

    Fail-safe inductive sensor GI761S

    Fail-safe inductive sensor GI762S

    Fail-safe inductive sensor GF854S

    Fail-safe inductive sensor GF711S

    Fail-safe inductive sensor GG712S

    Fail-safe inductive sensor GG711S

    Fail-safe inductive sensor GM705S

    Fail-safe inductive sensor GM701S

    Fail-safe inductive sensor GG507S

    Fail-safe inductive sensor GI712S

    Fail-safe inductive sensor GI701S

    Fail-safe inductive sensor GG505S

    Fail-safe inductive sensor GI711S

    Fail-safe inductive sensor GI505S

    Fail-safe inductive sensor GM505S

    Fail-safe inductive sensor GM504S

    Fail-safe inductive sensor GG851S

    Fail-safe inductive sensor GG714S

    Fail-safe inductive sensor GI506S

     

    Fail-safe inductive sensors

    Safety technology in automation has a share of the responsibility for safe human-machine interaction. Fail-safe sensors with safety functions are an important part of a safety system for persons and machines. The operating principle and thus the advantages of inductive sensors can also be used for safety-related applications. Direct detection of metal solves many applications. Magnetic or mechanical counterparts do not have to be considered in the design. A wear-free function due to the non-contact principle and a high protection rating guarantee high plant uptime.

    No special demands such as shielding, twisted cables or laying separately, are made on the socket. The sensor is directly connected to existing PLCs or logic modules using common existing unshielded 4-pole cables. The output characteristics of the sensor follow the characteristics of an input to EN 61131-2 type 1 or 2. The connection to ifm evaluation relays, the bus system AS-i Safety at Work, PROFIsafe, Interbus Safety or safe PLCs and logic modules is equally simple. For the unit family with dynamic pulse detection (Gx50xS) the corresponding software modules are required. The fail-safe sensors with 2 x PNP output (Gx70xS; Gx71xS) can be connected to approved two-channel safety relays without cross-monitoring. The evaluation units from ifm electronic additionally enable the connection of e-stop devices to DIN EN 60947-5-1 without extra cost.

    A magnet or coded target is not necessary for the function of the fail-safe sensor.

     

    -------------------------------------

    CÔNG TY CỔ PHẦN KỸ THUẬT VÀ THƯƠNG MẠI THIẾT BỊ CÔNG NGHIỆP NTD
    VPGD: Số 9, Ngõ 651/82/3 Minh Khai, Hai Bà Trưng, Hà Nội.
    Hotline: 0971961212
    Mail: sales@ntd-automation.com

    Tags: