
47NLDY CURRENT LOOP SUPPLY DIGITAL PANEL METER
47NLDY Digital Panel Meters 47NL Series
CURRENT LOOP SUPPLY DIGITAL PANEL METER
(4 1/2 digit, LED display type)
Functions & Features
• 4 ½ digit current loop supply digital panel meter
• Moving average function to suppress the display flickering
• Scaling, forced zero, low-end cutout
• Switchable between linear and square root extraction
• Max. and Min. value display
• Photo MOSFET relay alarm output
MODEL: 47NLDY-[1]-R[2]
ORDERING INFORMATION
• Code number: 47NLDY-[1]-R[2]
Specify a code from below for each [1] and [2].
(e.g. 47NLDY-B-R/Q)
• Specify the specification for option code /Q
(e.g. /SET)
INPUT
Current
4 – 20 mA DC (Input resistance 250 Ω)
[1] DISPLAY COLOR
R: Red
YR: Orange
G: Green
B: Blue
W: White
POWER INPUT
DC Power
R: 24 V DC
(Operational voltage range 24 V ±10 %, ripple 10 %p-p max.)
[2] OPTIONS
blank: none
/Q: With options (specify the specification)
SPECIFICATIONS OF OPTION: Q
EX-FACTORY SETTING
/SET: Preset according to the Ordering Information Sheet
(No. ESU-9567)
48NDT-41V2-R/CE Thermocouple K 4x Contacts
48NDT-42V2-R/CE Thermocouple K 4x Contacts
48NDT-41V4-R/CE Thermocouple J 4x Contacts
48NDT-42V4-R/CE Thermocouple J 4x Contacts
48NDR-41V4-R/CE RTD (PT50, PT100, Ni) 4x Contacts
48NDR-42V4-R/CE RTD (PT50, PT100, Ni) 4x Contacts
48NDM-41V-R/CE Potentiometer 0,1...10 kOhm 4x Contacts
48NDM-42V-R/CE Potentiometer 0,1...10 kOhm 4x Contacts
48NDV-4C1VA-R/CE 4...20 mA 4x Contacts
48NDV-4C1VD-R/CE 0...20 mA 4x Contacts
48NDV-4C1V4-R/CE 0...10 Vdc 4x Contacts
48NDV-4C1V6-R/CE 1...5 Vdc 4x Contacts
48NDV-4C2VA-R/CE 4...20 mA 4x Contacts
48NDV-4C2VD-R/CE 0...20 mA 4x Contacts
48NDV-4C2V4-R/CE 0...10 Vdc 4x Contacts
48NDV-4C2V6-R/CE 1...5 Vdc 4x Contacts
48NDT-4RV2-R/CE Thermocouple K 4x Contacts
48NDT-4YV2-R/CE Thermocouple K 4x Contacts
48NDT-4GV2-R/CE Thermocouple K 4x Contacts
48NDT-4RV4-R/CE Thermocouple J 4x Contacts
48NDT-4YV4-R/CE Thermocouple J 4x Contacts
48NDT-4GV4-R/CE Thermocouple J 4x Contacts
48NDR-4RV4-R/CE RTD (PT50, PT100, Ni) 4x Contacts
48NDR-4YV4-R/CE RTD (PT50, PT100, Ni) 4x Contacts
48NDR-4GV4-R/CE RTD (PT50, PT100, Ni) 4x Contacts
48NDM-4RV-R/CE Potentiometer 0,1...10 kOhm 4x Contacts
48NDM-4YV-R/CE Potentiometer 0,1...10 kOhm 4x Contacts
48NDM-4GV-R/CE Potentiometer 0,1...10 kOhm 4x Contacts
48NDV-4RVA-R/CE 4...20 mA 4x Contacts
48NDV-4RVD-R/CE 0...20 mA 4x Contacts
48NDV-4RV4-R/CE 0...10 Vdc 4x Contacts
48NDV-4RV6-R/CE 1...5 Vdc 4x Contacts
48NDV-4YVA-R/CE 4...20 mA 4x Contacts
48NDV-4YVD-R/CE 0...20 mA 4x Contacts
48NDV-4YV4-R/CE 0...10 Vdc 4x Contacts
48NDV-4YV6-R/CE 1...5 Vdc 4x Contacts
48NDV-4GVA-R/CE 4...20 mA 4x Contacts
48NDV-4GVD-R/CE 0...20 mA 4x Contacts
48NDV-4GV4-R/CE 0...10 Vdc 4x Contacts
48NDV-4GV6-R/CE 1...5 Vdc 4x Contacts
48NAT-41V2-R/CE Thermocouple K 4x Contacts
48NAT-42V2-R/CE Thermocouple K 4x Contacts
48NAT-41V4-R/CE Thermocouple J 4x Contacts
48NAT-42V4-R/CE Thermocouple J 4x Contacts
48NAT-41H2-R/CE Thermocouple K 4x Contacts
48NAT-42H2-R/CE Thermocouple K 4x Contacts
48NAT-41H4-R/CE Thermocouple J 4x Contacts
48NAT-42H4-R/CE Thermocouple J 4x Contacts
48NAR-41V4-R/CE RTD (PT50, PT100, Ni) 4x Contacts
48NAR-42V4-R/CE RTD (PT50, PT100, Ni) 4x Contacts
48NAR-41H4-R/CE RTD (PT50, PT100, Ni) 4x Contacts
48NAR-42H4-R/CE RTD (PT50, PT100, Ni) 4x Contacts
48NAM-41V-R/CE Potentiometer 0,1...10 kOhm 4x Contacts
48NAM-42V-R/CE Potentiometer 0,1...10 kOhm 4x Contacts
48NAM-41H-R/CE Potentiometer 0,1...10 kOhm 4x Contacts
48NAM-42H-R/CE Potentiometer 0,1...10 kOhm 4x Contacts
48NDT-21V2-R/CE Thermocouple K 2x changeover relay
48NDT-22V2-R/CE Thermocouple K 2x changeover relay
48NDT-21V4-R/CE Thermocouple J 2x changeover relay
48NDT-22V4-R/CE Thermocouple J 2x changeover relay
48NDR-21V4-R/CE RTD (PT50, PT100, Ni) 2x changeover relay
48NDR-22V4-R/CE RTD (PT50, PT100, Ni) 2x changeover relay
48NDM-21V-R/CE Potentiometer 0,1...10 kOhm 2x changeover relay
48NDM-22V-R/CE Potentiometer 0,1...10 kOhm 2x changeover relay
48NAV-4C1VA-R/CE 4...20 mA 4x Contacts
48NAV-4C1VD-R/CE 0...20 mA 4x Contacts
48NAV-4C1V4-R/CE 0...10 Vdc 4x Contacts
48NAV-4C1V6-R/CE 1...5 Vdc 4x Contacts
48NAV-4C2VA-R/CE 4...20 mA 4x Contacts
48NAV-4C2VD-R/CE 0...20 mA 4x Contacts
48NAV-4C2V4-R/CE 0...10 Vdc 4x Contacts
48NAV-4C2V6-R/CE 1...5 Vdc 4x Contacts
48NAV-4C1HA-R/CE 4...20 mA 4x Contacts
48NAV-4C1HD-R/CE 0...20 mA 4x Contacts
48NAV-4C1H4-R/CE 0...10 Vdc 4x Contacts
48NAV-4C1H6-R/CE 1...5 Vdc 4x Contacts
48NAV-4C2HA-R/CE 4...20 mA 4x Contacts
48NAV-4C2HD-R/CE 0...20 mA 4x Contacts
48NAV-4C2H4-R/CE 0...10 Vdc 4x Contacts
48NAV-4C2H6-R/CE 1...5 Vdc 4x Contacts
48NAVD-41V-R/CE 4...20 mA, Loop 4x Contacts
48NAVD-41H-R/CE 4...20 mA, Loop 4x Contacts
48NAVD-42V-R/CE 4...20 mA, Loop 4x Contacts
48NAVD-42H-R/CE 4...20 mA, Loop 4x Contacts
48NDV-2C1VA-R/CE 4...20 mA 2x changeover relay
48NDV-2C1VD-R/CE 0...20 mA 2x changeover relay
48NDV-2C1V4-R/CE 0...10 Vdc 2x changeover relay
48NDV-2C1V6-R/CE 1...5 Vdc 2x changeover relay
48NDV-2C2VA-R/CE 4...20 mA 2x changeover relay
48N