SPE REPEATER BA8NS-CONV

Liên hệ Còn hàng

BA8NS-CONV

SPE Remote I/O BA8 Series

SPE CONVERTER

Functions & Features
• Equipped with SPE (10BASE-T1L) and LAN (RJ-45) ports.
• Modbus/TCP transparent.

MODEL: BA8NS-CONV-[1]

ORDERING INFORMATION

• Code number: BA8NS-CONV-[1]
Specify a code from below for [1].
  (e.g. BA8NS-CONV-M2)

 

[1] POWER INPUT

AC Power
M2: 100 – 240 V AC (Operational voltage range 85 – 264 V,
 47 – 66 Hz)
DC Power
R: 24 V DC
(Operational voltage range 24 V ±10 %, ripple 10 %p-p max.)

 

GENERAL SPECIFICATIONS

Construction: Stand-alone
Connection:
· Power
  Unit side connector: MSTB2,5/3-G (Phoenix Contact)
  Cable side connector: MSTB2,5/3-ST (Phoenix Contact)
  Applicable wire size: 0.2 - 2.5mm
2, stripped length 7mm
· LAN
  Modular jack for 10BASE-T / 100BASE-TX (RJ-45)
· 10BASE-T1L
  Unit side connector: in-house made
  Applicable connector: DFMC1,5/2-ST-3,5 (Phoenix Contact) (included in the package)
  Applicable wire size: 0.2 - 1.5mm
2, stripped length 10mm
Isolation: LAN to SPE to power to FE

 

COMMUNICATION

Number of connected client: 1
■ Ethernet
Communication standard
: IEEE 802.3u
Transmission type: 10BASE-T, 100BASE-TX
Transmission speed: 10/100 Mbps
(Auto Negotiation)
Transmission media:
10BASE-T (STP cable; Category 5)
100BASE-TX (STP cable; Category 5e)
Maximum segment length: 100 meters
■ 10BASE-T1L
Communication standard
: IEEE 802.3cg
Transmission speed: 10 Mbps
Transmission media: CAT5 2-wire twisted-pair
Maximum segment length: 1000 meters (standard value)

 

INSTALLATION

Power consumption
•AC:
 Approx. 1.8 VA at 100 V
 Approx. 2.3 VA at 200 V
 Approx. 3 VA at 264 V
•DC: Approx. 0.8 W
Operating temperature: -10 to +55°C (14 to 131°F)
Operating humidity: 10 to 90 %RH (non-condensing)
Ambience: No corrosive gas or heavy dust; no strong electric/magnetic field; no direct effect of vibration or physical impact
Mounting: DIN rail
Weight: 100 g (0.22 lb)

 

PERFORMANCE

Insulation resistance: ≥ 100 MΩ with 500 V DC
Dielectric strength: 1500 V AC @1 minute
(LAN or SPE to power to FE)
500 V AC @ 1 minute (LAN to SPE)

 

REFERENCE DATA

The data shown below are of individual test pieces and do not guarantee all values.
· 10BASE-T1L transmission distance test
Used cable 1

Category 6 twisted pair cable from ELECOM
LD-CT6
Transmission distance: 970 m
Communication establishment time: Approx. 7 sec.
Used cable 2
Electric button telephone cable from TSUKO DKT-Q0.5-2P
Transmission distance: 600 m
Communication establishment time: Approx. 0.5 sec.

 

--------------------

CÔNG TY CỔ PHẦN KỸ THUẬT VÀ THƯƠNG MẠI THIẾT BỊ CÔNG NGHIỆP NTD

Adress: No. 28, Alley 36 Co Linh Street, Group 7, Long Bien Ward, Long Bien District, Hanoi City, Vietnam.

Hotline: 0971961212

Mail: sales@ntd-automation.com

 

 

Tags: