Bộ Lọc Quản Lý Nhiên Liệu - Racor FM Series-Parker
oạt lọc Racor Fuel Manager loại bỏ nước dư và có van xả tiện lợi.
| Products | Sê-ri sản phẩm | Loại bộ lọc | Kích cỡ cổng | Xếp hạng Micron |
|---|---|---|---|---|
| 29367 | FM100 | Final Filter | In:3/8" (90°) | 5 μm |
| 30481 | FM100 | Final Filter | In: 3/8" (0°) | 5 μm |
| 33640 | FM100 | Pre-filter | 3/8-18 NPT | 150 μm |
| 33641 | FM100 | Pre-filter | 3/8-18 NPT | 30 μm |
| 33642 | FM100 | Final Filter | 3/8-18 NPT | 5 μm |
| 33643 | FM100 | Pre-filter | 3/8-18 NPT | 150 μm |
| 33644 | FM100 | Pre-filter | 3/8-18 NPT | 30 μm |
| 33645 | FM100 | Final Filter | 3/8-18 NPT | 5 μm |
| 33686 | FM1000 | Final Filter | ½" - 14 NPT | 5 μm |
| 33688 | FM1000 | Pre-filter | 1/2-14 NPT | 30 μm |
| 33690 | FM1000 | Final Filter | ½" - 14 NPT | 5 μm |
| 33692 | FM1000 | Pre-filter | 1/2-14 NPT | 30 μm |
| 33694 | FM1000 | Final Filter | ⅞" - 14 | 5 μm |
| 33696. | FM1000 | Pre-filter | ⅞" - 14 | 30 μm |
| 33698 | FM1000 | Final Filter | ⅞" - 14 | 5 μm |
| 33700 | FM1000 | Pre-filter | ⅞" - 14 | 30 μm |
| 33816 | FM100 | Pre-filter | 1/4-18 NPT | 30 μm |
| 33945 | FM100 | Final Filter | ¼" - 18 NPT | 5 μm |
| 34817 | FM100 | Pre-filter | M12 x 1.5 | 150 μm |
| 34818 | FM100 | Pre-filter | M14 x 1.5 | 150 μm |
| 34819 | FM100 | Pre-filter | M12 x 1.5 | 30 μm |
| 34820 | FM100 | Pre-filter | M14 x 1.5 | 30 μm |
| 34821 | FM100 | Final Filter | M12 x 1.5 | 5 μm |
| 34822 | FM100 | Final Filter | M14 x 1.5 | 5 μm |
| 35599 | FM100 | Pre-filter | 3/8-18 NPT | 150 μm |
| 35726 | FM100 | Final Filter | 1/4-18 NPT | 5 μm |
| 36224 | FM1000 | Pre-filter | M22 x 1.5 | 150 μm |
| 36691 | FM10 | Final Filter | - | 5 μm |
| 36694 | FM100 | Final Filter | 1/4-18 NPT | 2 μm |
| 36996 | FM10 | Final Filter | - | 5 μm |
| 37776 | FM1000 | Final Filter | ⅞" - 14 | 5 μm |
| 37865 | FM10 | Final Filter | - | 5 μm |
| 38630 | FM100 | Final Filter | 1/4-18 NPT | 5 μm |
| 39359 | FM100 | Final Filter | M14 x 1.5, M16 x 1.5 | 5 μm |
| 39452 | FM100 | Pre-filter | 3/8-18 NPT | 30 μm |
| 40074 | FM1 | Final Filter | - | 5 μm |
| 40253 | FM100 | Pre-filter | M14 x 1.5 | 30 μm |
| 40601 | FM1000 | Final Filter | ⅞" - 14 | 5 μm |
| 40954 | FM100 | Pre-filter | 1/4-18 NPT | 30 μm |
| 40957 | FM100 | Pre-filter | 1/4-18 NPT | 30 μm |
| 41341 | FM100 | Pre-filter | M12 x 1.5 | 30 μm |
| 41342 | FM100 | Pre-filter | M12 x 1.5 | 30 μm |
| 41343 | FM100 | Pre-filter | M14 x 1.5 | 30 μm |
| 41344 | FM100 | Pre-filter | M14 x 1.5 | 30 μm |
| 41467 | FM1 | Final Filter | - | 5 μm |
| 41775 | FM100 | Final Filter | ¼" - 18 NPT | 5 μm |
| 42049 | FM100 | Pre-filter | M14 x 1.5 | 30 μm |
| 42050 | FM100 | Final Filter | M14 x 1.5 | 2 μm |
| 42093 | FM100 | Pre-filter | 1/4-18 NPT | 30 μm |
| 42145 | FM1 | Pre-filter | - | 30 μm |
| 42468 | FM100 | Final Filter | ¼" - 18 NPTF | 5 μm |
| 42533 | FM100 | Final Filter | 1/4-18 NPT | 2 μm |
| 42925 | FM1000 | Pre-filter | M22 x 1.5 | 30 μm |
| 42939 | FM1000 | Final Filter | M22 x 1.5 | 5 μm |
| 42946 | FM100 | Final Filter | ⅜" - 18 NPTF | 2 μm |
| 42963 | FM100 | Final Filter | ½ - 20 UNF | 2μm |
| 43097 | FM100 | Pre-filter | 1/4-18 NPT | 30 μm |
| 43098 | FM100 | Final Filter | 1/4-18 NPT | 2 μm |
| 43374 | FM100 | Final Filter | M14 x 1.5 | 5 μm |
| 43698 | FM100 | Pre-filter | 1/4-18 NPT | 10 μm |
| 44760 | FM100 | Final Filter | 1/4-18 NPT | 5 μm |
| 35726P | FM100 | Final Filter | ½ - 20 UNF | 2μm |
------------------------
Nhà phân phối sản phẩm Parker tại Việt Nam - Parker Vietnam Distributor
CÔNG TY CỔ PHẦN KỸ THUẬT VÀ THƯƠNG MẠI THIẾT BỊ CÔNG NGHIỆP NTD
Adress: No. 28, Alley 36 Co Linh Street, Group 7, Long Bien Ward, Long Bien District, Hanoi City, Vietnam.
Hotline: 0971961212
Mail: sales@ntd-automation.com