| Products | Tốc độ dòng chảy | Kích cỡ cổng | Áp lực làm việc |
|---|---|---|---|
| STH001N | 54 m³/h @ 7 barg (32 cfm @ 102 psig) | ⅜" | Maximum: 16 barg |
| STH002N | 126 m³/h @ 7 barg (74 cfm @ 102 psig) | ½" | Maximum: 16 barg |
| STH003N | 180 m³/h @ 7 barg (106 cfm @ 102 psig) | ¾" | Maximum: 16 barg |
| STH006N | 330 m³/h @ 7 barg (194 cfm @ 102 psig) | 1" | Maximum: 16 barg |
| STH009N | 540 m³/h @ 7 barg (318 cfm @ 102 psig) | 1¼" | Maximum: 16 barg |
| STH013N | 750 m³/h @ 7 barg (441 cfm @ 102 psig) | 1½" | Maximum: 16 barg |
| STH021N | 1260 m³/h @ 7 barg (742 cfm @ 102 psig) | 2" | Maximum: 16 barg |
| STH040N | 2400 m³/h @ 7 barg (1413 cfm @ 102 psig) | 2½" | Maximum: 16 barg |
| STH046N | 2760 m³/h @ 7 barg (1625 cfm @ 102 psig) | 3" | Maximum: 16 barg |
| STH001A | 54 m³/h @ 7 barg (32 cfm @ 102 psig) | ⅜" | Maximum: 16 barg |
| STH003A | 180 m³/h @ 7 barg (106 cfm @ 102 psig) | 1½" | Maximum: 16 barg |
| STH013A | 750 m³/h @ 7 barg (441 cfm @ 102 psig) | 2" | Maximum: 16 barg |
| SFH066N | 3936 m³/h @ 7 barg (2317 cfm @ 102 psig) | DN 125 | Maximum: 16 barg |
| SFH067N | 4020 m³/h @ 7 barg (2366 cfm @ 102 psig) | DN 150 | Maximum: 16 barg |
| SFH088N | 5304 m³/h @ 7 barg (3122 cfm @ 102 psig) | DN 150 | Maximum: 16 barg |
| SFH089N | 5340 m³/h @ 7 barg (3143 cfm @ 102 psig) | DN 200 | Maximum: 16 barg |
| SFH097N | 5826 m³/h @ 7 barg (3429 cfm @ 102 psig) | DN 200 | Maximum: 16 barg |
| SFH142N | 8514 m³/h @ 7 barg (5011 cfm @ 102 psig) | DN 250 | Maximum: 10 barg |
| SFH180N | 10770 m³/h @ 7 barg (6339 cfm @ 102 psig) | DN 300 | Maximum: 10 barg |
| SFH209N | 12546 m³/h @ 7 barg (7385 cfm @ 102 psig) | DN 350 | Maximum: 9 barg |
| SFH280N | 16800 m³/h @ 7 barg (9888 cfm @ 102 psig) | DN 350 | Maximum: 9 barg |
| SFH390N | 23400 m³/h @ 7 barg (13773 cfm @ 102 psig) | DN 450 | Maximum: 10 barg |
| SFH450N | 27000 m³/h @ 7 barg (15892 cfm @ 102 psig) | DN 500 | Maximum: 10 barg |
| SFH550N | 33000 m³/h @ 7 barg (19424 cfm @ 102 psig) | DN 600 | Maximum: 10 barg |
| SFV029N | 1764 m³/h @ 7 barg (1038 cfm @ 102 psig) | DN 80 | Maximum: 16 barg |
| SFV037N | 2195 m³/h @ 7 barg (1292 cfm @ 102 psig) | DN 100 | Maximum: 12 barg |
| SFV066N | 3936 m³/h @ 7 barg (2317 cfm @ 102 psig) | DN 125 | Maximum: 12 barg |
| SFV088N | 5304 m³/h @ 7 barg (3122 cfm @ 102 psig) | DN 150 | Maximum: 12 barg |
| SFV097N | 5826 m³/h @ 7 barg (3429 cfm @ 102 psig) | DN 200 | Maximum: 12 barg |
| SFV142N | 8514 m³/h @ 7 barg (5011 cfm @ 102 psig) | DN 250 | Maximum: 10 barg |
| SFV180N | 10770 m³/h @ 7 barg (6339 cfm @ 102 psig) | DN 300 | Maximum: 10 barg |
| SFV209N | 12546 m³/h @ 7 barg (7385 cfm @ 102 psig) | DN 350 | Maximum: 9 barg |
| SFH019A | 1140 m³/h @ 7 barg (671 cfm @ 102 psig) | DN 65 | Maximum: 16 barg |
| SFH029A | 1764 m³/h @ 7 barg (1038 cfm @ 102 psig) | DN 80 | Maximum: 16 barg |
| SFH037A | 2196 m³/h @ 7 barg (1293 cfm @ 102 psig) | DN 100 | Maximum: 16 barg |
| SFH066A | 3936 m³/h @ 7 barg (2317 cfm @ 102 psig) | DN 125 | Maximum: 16 barg |
| SFH088A | 5304 m³/h @ 7 barg (3122 cfm @ 102 psig) | DN 150 | Maximum: 16 barg |
| SFH097A | 5826 m³/h @ 7 barg (3429 cfm @ 102 psig) | DN 200 | Maximum: 16 barg |
| STH003A-C | 180 m³/h @ 7 barg (106 cfm @ 102 psig) | DN25 | Maximum: 16 or 20 barg |
| STH013A-C | 750 m³/h @ 7 barg (441 cfm @ 102 psig) | DN40 | Maximum: 16 or 20 barg |
| SFH029N | 1764 m³/h @ 7 barg (1038 cfm @ 102 psig) | DN 80 | Maximum: 16 barg |
| SFH030N | 1800 m³/h @ 7 barg (1059 cfm @ 102 psig) | DN 100 | Maximum: 16 barg |
| SFH037N | 2196 m³/h @ 7 barg (1293 cfm @ 102 psig) | DN 100 | Maximum: 16 barg |
| SFH038N | 2280 m³/h @ 7 barg (1342 cfm @ 102 psig) | DN 125 | Maximum: 16 barg |
------------------------