Các Bộ Lọc Không Khí Nén Thay Thế Tương Thích của Par Fit- Parker
Các lõi lọc khí nén thay thế hiệu quả cao cho nhiều thương hiệu.
| Products | Thuốc gốc | Element |
|---|---|---|
| PR1060001 | Atlas Copco | DDp9 |
| PR2091230 | Donaldson | MF30/50 |
| PR1690760 | Hankison | E-9-36 |
| PR1690750 | Hankison | E-9-32 |
| PR1690740 | Hankison | E-9-28 |
| PR1690730 | Hankison | E-9-24 |
| PR1690720 | Hankison | E-9-20 |
| PR2091235 | Donaldson | SMF02/05 |
| PR1690710 | Hankison | E-9-16 |
| PR1690610 | Hankison | E-1-54 |
| PR1690600 | Hankison | E-1-52 |
| PR1690590 | Hankison | E-1-48 |
| PR1690580 | Hankison | E-1-44 |
| PR1690570 | Hankison | E-1-40 |
| PR1690560 | Hankison | E-1-32 |
| PR1690700 | Hankison | E-9-12 |
| PR1690550 | Hankison | E-1-28 |
| PR2091236 | Donaldson | SMF03/05 |
| PR2091250 | Donaldson | SMF03/10 |
| PR2091360 | Donaldson | AK02/10 |
| PR2091356 | Donaldson | AK03/05 |
| PR2091355 | Donaldson | AK02/05 |
| PR2091350 | Donaldson | SMF30/50 |
| PR2091340 | Donaldson | SMF30/30 |
| PR2091330 | Donaldson | SMF20/30 |
| PR2091240 | Donaldson | SMF02/10 |
| PR2091320 | Donaldson | SMF15/30 |
| PR2091300 | Donaldson | SMF07/30 |
| PR2091290 | Donaldson | SMF07/25 |
| PR2091280 | Donaldson | SMF05/25 |
| PR2091270 | Donaldson | SMF05/20 |
| PR2091260 | Donaldson | SMF04/20 |
| PR2091255 | Donaldson | SMF04/10 |
| PR2091310 | Donaldson | SMF10/30 |
| PR2091370 | Donaldson | AK03/10 |
| PR1690530 | Hankison | E-1-24 |
| PR1690510 | Hankison | E-1-16 |
| PR2091200 | Donaldson | MF15/30 |
| PR2091190 | Donaldson | MF10/30 |
| PR2091180 | Donaldson | MF07/30 |
| PR2091170 | Donaldson | MF07/25 |
| PR2091160 | Donaldson | MF05/25 |
| PR2091150 | Donaldson | MF05/20 |
| PR2091210 | Donaldson | MF20/30 |
| PR2091140 | Donaldson | MF04/20 |
| PR2091130 | Donaldson | MF03/10 |
| PR2091120 | Donaldson | MF02/10 |
| PR2091116 | Donaldson | MF03/05 |
| PR2091115 | Donaldson | MF02/05 |
| PR2091110 | Donaldson | PE30/50 or SB30/50 |
| PR2091100 | Donaldson | PE30/30 or SB30/30 |
| PR2091135 | Donaldson | MF04/10 |
| PR1690520 | Hankison | E-1-20 |
| PR2091220 | Donaldson | MF30/30 |
| PR1690200 | Hankison | E-7-52 |
| PR1690500 | Hankison | E-1-12 |
| PR1690410 | Hankison | E-5-54 |
| PR1690400 | Hankison | E-5-52 |
| PR1690390 | Hankison | E-5-48 |
| PR1690380 | Hankison | E-5-44 |
| PR1690370 | Hankison | E-5-40 |
| PR1690190 | Hankison | E-7-48 |
| PR1690360 | Hankison | E-5-36 |
| PR1690340 | Hankison | E-5-28 |
| PR1690330 | Hankison | E-5-24 |
| PR1690320 | Hankison | E-5-20 |
| PR1690310 | Hankison | E-5-16 |
| PR1690300 | Hankison | E-5-12 |
| PR1690210 | Hankison | E-7-54 |
| PR1690350 | Hankison | E-5-32 |
| PR2091090 | Donaldson | PE20/30 or SB20/30 |
| PR2091375 | Donaldson | AK04/10 |
| PR2091390 | Donaldson | AK05/20 |
| PR2098070 | Donaldson | FF10/3 |
| PR2098065 | Donaldson | FF7/3 |
| PR2098060 | Donaldson | FF5/3 |
| PR2098050 | Donaldson | FF5/2.5 |
| PR2098040 | Donaldson | FF4/2.5 |
| PR2098030 | Donaldson | FF4/1.5 |
| PR2098075 | Donaldson | FF12/3 |
| PR2098020 | Donaldson | FF3/1.5 |
| PR2090230 | Donaldson | MF2/1.5 |
| PR2090220 | Donaldson | MF3/1 |
| PR2090210 | Donaldson | SMF30/5 |
| PR2090190 | Donaldson | SMF30/3 |
| PR2090180 | Donaldson | SMF20/3 |
| PR2090170 | Donaldson | SMF15/3 |
| PR2090240 | Donaldson | MF3/1.5 |
| PR2090165 | Donaldson | SMF12/3 |
| PR2098080 | Donaldson | FF15/3 |
| PR2098100 | Donaldson | FF30/3 |
| PR2098240 | Donaldson | FF20/30 |
| PR2098230 | Donaldson | FF15/30 |
| PR2098220 | Donaldson | FF10/30 |
| PR2098210 | Donaldson | FF07/30 |
| PR2098200 | Donaldson | FF07/25 |
| PR2098190 | Donaldson | FF05/25 |
| PR2098090 | Donaldson | FF20/3 |
| PR2098180 | Donaldson | FF05/20 |
| PR2098160 | Donaldson | FF04/10 |
------------------------
Nhà phân phối sản phẩm Parker tại Việt Nam - Parker Vietnam Distributor
CÔNG TY CỔ PHẦN KỸ THUẬT VÀ THƯƠNG MẠI THIẾT BỊ CÔNG NGHIỆP NTD
Adress: No. 28, Alley 36 Co Linh Street, Group 7, Long Bien Ward, Long Bien District, Hanoi City, Vietnam.
Hotline: 0971961212
Mail: sales@ntd-automation.com






