Compact transmitters for industrial use
Compact transmitters for industrial use
- Units with long temperature measurement range
- Very short response time
- High mechanical stability and pressure rating up to 400 bar
- High protection rating for the requirements of harsh industrial environments
- Different installation lengths from 25...150 mm
Temperature transmitter TA2145
Temperature transmitter TA2115
Temperature transmitter TA2105
Temperature transmitter TA2603
Temperature transmitter TA2613
Temperature transmitter TA2417
Temperature transmitter TA2415
Temperature transmitter TA2435
Temperature transmitter TA2135
Temperature transmitter TA2232
Temperature transmitter TA2437
Temperature transmitter TA2333
Temperature transmitter TA2242
Temperature transmitter TA2405
Temperature transmitter TA2262
Temperature transmitter TA2313
Temperature transmitter TA2241
Temperature transmitter TA2303
Temperature transmitter TA2343
Temperature transmitter TA2445
Temperature transmitter TA2447
Temperature transmitter TA2292
Temperature transmitter TA2212
Temperature transmitter TA2633
Temperature transmitter TA2643
Temperature transmitter TA2247
Temperature transmitter TA2345
Temperature sensor with IO-Link TV7105
Temperature sensor with IO-Link TV7303
Temperature sensor with IO-Link TV7603
Temperature sensor with IO-Link TV7405
Temperature transmitter TAA131
Temperature transmitter TAA431
Compact transmitters for industrial applications
The compact temperature transmitters are specially designed for use in process applications. They have an analogue output with 4...20 mA.
The Pt1000 measuring element of class A achieves a high precision with the factory-internal calibration. The innovation besides the wide measuring range is the excellent response time. Thanks to their high protection rating, fully welded stainless steel housing and high pressure resistance, the transmitters are particularly suited for use in harsh industrial environments. An LED clearly signals the readiness for operation.
The sensors are available with different probe lengths, process connections and measuring ranges. A variety of adapters facilitates integration into the process.
The units can either be used as 2-wire or 4-wire units. When used as a 4-wire unit, the transmitter can be configured via IO-Link, e.g. using a USB interface. The LINERECORDER SENSOR software is used to visualise, transfer and archive parameter sets.
-------------------------------------
CÔNG TY CỔ PHẦN KỸ THUẬT VÀ THƯƠNG MẠI THIẾT BỊ CÔNG NGHIỆP NTD
VPGD: Số 9, Ngõ 651/82/3 Minh Khai, Hai Bà Trưng, Hà Nội.
Hotline: 0971961212
Mail: sales@ntd-automation.com






