Bộ lọc khí nén áp suất cao GH Series (cho áp suất lên đến 100 bar g)
Bộ lọc áp suất cao cho khí nén tối đa 100 bar, hiệu suất cao.
| Products | Loại bộ lọc | Tốc độ dòng chảy |
| GH3/100XP | Oil Removal Filter | 188 m³/hr @ 100 barg (111 cfm @ 1450 psig) |
| GH3/100ZP | Coalescing & Dry Particulate | 188 m³/hr @ 100 barg (111 cfm @ 1450 psig) |
| GH3/100V | Dry Particulate | 188 m³/hr @ 100 barg (111 cfm @ 1450 psig) |
| GH3/100A | Oil Vapour Reduction | 188 m³/hr @ 100 barg (111 cfm @ 1450 psig) |
| GH3/100VOA | Dry Particulate | 188 m³/hr @ 100 barg (111 cfm @ 1450 psig) |
| GH3/100ZPOA | Coalescing & Dry Particulate | 188 m³/hr @ 100 barg (111 cfm @ 1450 psig) |
| GH5/100XP | Oil Removal Filter | 268 m³/hr @ 100 barg (158 cfm @ 1450 psig) |
| GH5/100ZP | Coalescing & Dry Particulate | 268 m³/hr @ 100 barg (158 cfm @ 1450 psig) |
| GH5/100V | Dry Particulate | 268 m³/hr @ 100 barg (158 cfm @ 1450 psig) |
| GH5/100A | Oil Vapour Reduction | 268 m³/hr @ 100 barg (158 cfm @ 1450 psig) |
| GH5/100VOA | Dry Particulate | 268 m³/hr @ 100 barg (158 cfm @ 1450 psig) |
| GH5/100ZPOA | Coalescing & Dry Particulate | 268 m³/hr @ 100 barg (158 cfm @ 1450 psig) |
| GH7/100XP | Oil Removal Filter | 469 m³/hr @ 100 barg (276 cfm @ 1450 psig) |
| GH7/100ZP | Coalescing & Dry Particulate | 469 m³/hr @ 100 barg (276 cfm @ 1450 psig) |
| GH7/100V | Dry Particulate | 469 m³/hr @ 100 barg (276 cfm @ 1450 psig) |
| GH7/100A | Oil Vapour Reduction | 469 m³/hr @ 100 barg (276 cfm @ 1450 psig) |
| GH7/100VOA | Dry Particulate | 469 m³/hr @ 100 barg (276 cfm @ 1450 psig) |
| GH7/100ZPOA | Coalescing & Dry Particulate | 469 m³/hr @ 100 barg (276 cfm @ 1450 psig) |
| GH9/100XP | Oil Removal Filter | 681 m³/hr @ 100 barg (401 cfm @ 1450 psig) |
| GH9/100ZP | Coalescing & Dry Particulate | 681 m³/hr @ 100 barg (401 cfm @ 1450 psig) |
| GH9/100V | Dry Particulate | 681 m³/hr @ 100 barg (401 cfm @ 1450 psig) |
| GH9/100A | Oil Vapour Reduction | 681 m³/hr @ 100 barg (401 cfm @ 1450 psig) |
| GH9/100VOA | Dry Particulate | 681 m³/hr @ 100 barg (401 cfm @ 1450 psig) |
| GH9/100ZPOA | Coalescing & Dry Particulate | 681 m³/hr @ 100 barg (401 cfm @ 1450 psig) |
| GH11/100XP | Oil Removal Filter | 1203 m³/hr @ 100 barg (708 cfm @ 1450 psig) |
| GH11/100ZP | Coalescing & Dry Particulate | 1203 m³/hr @ 100 barg (708 cfm @ 1450 psig) |
| GH11/100V | Dry Particulate | 1203 m³/hr @ 100 barg (708 cfm @ 1450 psig) |
| GH11/100A | Oil Vapour Reduction | 1203 m³/hr @ 100 barg (708 cfm @ 1450 psig) |
| GH11/100VOA | Dry Particulate | 1203 m³/hr @ 100 barg (708 cfm @ 1450 psig) |
| GH11/100ZPOA | Coalescing & Dry Particulate | 1203 m³/hr @ 100 barg (708 cfm @ 1450 psig) |
| GH12/100XP | Oil Removal Filter | 1857 m³/hr @ 100 barg (1093 cfm @ 1450 psig) |
| GH12/100ZP | Coalescing & Dry Particulate | 1857 m³/hr @ 100 barg (1093 cfm @ 1450 psig) |
| GH12/100V | Dry Particulate | 1857 m³/hr @ 100 barg (1093 cfm @ 1450 psig) |
| GH12/100A | Oil Vapour Reduction | 1857 m³/hr @ 100 barg (1093 cfm @ 1450 psig) |
| GH12/100VOA | Dry Particulate | 1857 m³/hr @ 100 barg (1093 cfm @ 1450 psig) |
| GH12/100ZPOA | Coalescing & Dry Particulate | 1857 m³/hr @ 100 barg (1093 cfm @ 1450 psig) |
| GH13/100XP | Oil Removal Filter | 2787 m³/hr @ 100 barg (1640 cfm @ 1450 psig) |
| GH13/100ZP | Coalescing & Dry Particulate | 2787 m³/hr @ 100 barg (1640 cfm @ 1450 psig) |
| GH13/100V | Dry Particulate | 2787 m³/hr @ 100 barg (1640 cfm @ 1450 psig) |
| GH13/100A | Oil Vapour Reduction | 2787 m³/hr @ 100 barg (1640 cfm @ 1450 psig) |
| GH13/100VOA | Dry Particulate | 2787 m³/hr @ 100 barg (1640 cfm @ 1450 psig) |
| GH13/100ZPOA | Coalescing & Dry Particulate | 2787 m³/hr @ 100 barg (1640 cfm @ 1450 psig) |
------------------------
Nhà phân phối sản phẩm Parker tại Việt Nam - Parker Vietnam Distributor
CÔNG TY CỔ PHẦN KỸ THUẬT VÀ THƯƠNG MẠI THIẾT BỊ CÔNG NGHIỆP NTD
Adress: No. 28, Alley 36 Co Linh Street, Group 7, Long Bien Ward, Long Bien District, Hanoi City, Vietnam.
Hotline: 0971961212
Mail: sales@ntd-automation.com