Hệ thống làm mát dầu bằng không khí hoàn chỉnh với động cơ AC - Serie ULOC - (Châu Mỹ)
Dòng ULOC giúp làm mát hiệu quả, thiết kế gọn, tuổi thọ cao, tới 60hp.
| Products | Loại motor |
| ULOC-007D-M-A-SA | Three Phase, 190/380V 50 Hz, 208-230/460V 60 Hz |
| ULOC-007D-M-A-SB | Three Phase, 190/380V 50 Hz, 208-230/460V 60 Hz |
| ULOC-007D-M-A-SW | Three Phase, 190/380V 50 Hz, 208-230/460V 60 Hz |
| ULOC-007D-M-B-SA | Three Phase, 190/380V 50 Hz, 208-230/460V 60 Hz |
| ULOC-007D-M-B-SB | Three Phase, 190/380V 50 Hz, 208-230/460V 60 Hz |
| ULOC-007D-Q-B-SW | Three Phase, 575V, 60 Hz |
| ULOC-007D-W-A-SA | No motor |
| ULOC-007D-W-A-SB | No motor |
| ULOC-007D-W-A-SW | No motor |
| ULOC-007D-W-B-SA | No motor |
| ULOC-007D-W-B-SB | No motor |
| ULOC-023F-Q-D-SW | Three Phase, 575V, 60 Hz |
| ULOC-023F-W-C-SA | No motor |
| ULOC-023F-W-C-SB | No motor |
| ULOC-023F-W-C-SW | No motor |
| ULOC-023F-W-D-SA | No motor |
| ULOC-023F-W-D-SB | No motor |
| ULOC-007D-W-B-SW | No motor |
| ULOC-007E-M-C-SA | Three Phase, 190/380V 50 Hz, 208-230/460V 60 Hz |
| ULOC-007E-M-C-SB | Three Phase, 190/380V 50 Hz, 208-230/460V 60 Hz |
| ULOC-007E-M-C-SW | Three Phase, 190/380V 50 Hz, 208-230/460V 60 Hz |
| ULOC-007E-M-D-SA | Three Phase, 190/380V 50 Hz, 208-230/460V 60 Hz |
| ULOC-007E-M-D-SB | Three Phase, 190/380V 50 Hz, 208-230/460V 60 Hz |
| ULOC-007E-M-D-SW | Three Phase, 190/380V 50 Hz, 208-230/460V 60 Hz |
| ULOC-007E-Q-C-SA | Three Phase, 575V, 60 Hz |
| ULOC-007E-Q-C-SB | Three Phase, 575V, 60 Hz |
| ULOC-007E-Q-C-SW | Three Phase, 575V, 60 Hz |
| ULOC-007E-Q-D-SA | Three Phase, 575V, 60 Hz |
| ULOC-007E-Q-D-SB | Three Phase, 575V, 60 Hz |
| ULOC-033G-M-D-SW | Three Phase, 190/380V 50 Hz, 208-230/460V 60 Hz |
| ULOC-033G-Q-C-SA | Three Phase, 575V, 60 Hz |
| ULOC-033G-Q-C-SB | Three Phase, 575V, 60 Hz |
| ULOC-033G-Q-C-SW | Three Phase, 575V, 60 Hz |
| ULOC-033G-Q-D-SA | Three Phase, 575V, 60 Hz |
| ULOC-033G-Q-D-SB | Three Phase, 575V, 60 Hz |
| ULOC-007E-Q-D-SW | Three Phase, 575V, 60 Hz |
| ULOC-007E-W-C-SA | No motor |
| ULOC-007E-W-C-SB | No motor |
| ULOC-007E-W-C-SW | No motor |
| ULOC-007E-W-D-SA | No motor |
| ULOC-007E-W-D-SB | No motor |
| ULOC-033G-Q-D-SW | Three Phase, 575V, 60 Hz |
| ULOC-033G-W-C-SA | No motor |
| ULOC-033G-W-C-SB | No motor |
| ULOC-033G-W-C-SW | No motor |
| ULOC-033G-W-D-SA | No motor |
| ULOC-033G-W-D-SB | No motor |
| ULOC-007E-W-D-SW | No motor |
| ULOC-011D-M-A-SA | Three Phase, 190/380V 50 Hz, 208-230/460V 60 Hz |
| ULOC-011D-M-A-SB | Three Phase, 190/380V 50 Hz, 208-230/460V 60 Hz |
| ULOC-011D-M-A-SW | Three Phase, 190/380V 50 Hz, 208-230/460V 60 Hz |
| ULOC-011D-M-B-SA | Three Phase, 190/380V 50 Hz, 208-230/460V 60 Hz |
| ULOC-011D-M-B-SB | Three Phase, 190/380V 50 Hz, 208-230/460V 60 Hz |
| ULOC-033G-W-D-SW | No motor |
| ULOC-044G-M-C-SA | Three Phase, 190/380V 50 Hz, 208-230/460V 60 Hz |
| ULOC-044G-M-C-SB | Three Phase, 190/380V 50 Hz, 208-230/460V 60 Hz |
| ULOC-044G-M-C-SW | Three Phase, 190/380V 50 Hz, 208-230/460V 60 Hz |
| ULOC-044G-M-D-SA | Three Phase, 190/380V 50 Hz, 208-230/460V 60 Hz |
| ULOC-044G-M-D-SB | Three Phase, 190/380V 50 Hz, 208-230/460V 60 Hz |
| ULOC-011D-M-B-SW | Three Phase, 190/380V 50 Hz, 208-230/460V 60 Hz |
| ULOC-011D-Q-A-SA | Three Phase, 575V, 60 Hz |
| ULOC-011D-Q-A-SB | Three Phase, 575V, 60 Hz |
| ULOC-011D-Q-A-SW | Three Phase, 575V, 60 Hz |
| ULOC-011D-Q-B-SA | Three Phase, 575V, 60 Hz |
| ULOC-011D-Q-B-SB | Three Phase, 575V, 60 Hz |
| ULOC-044G-M-D-SW | Three Phase, 190/380V 50 Hz, 208-230/460V 60 Hz |
| ULOC-044G-Q-C-SA | Three Phase, 575V, 60 Hz |
| ULOC-044G-Q-C-SB | Three Phase, 575V, 60 Hz |
| ULOC-044G-Q-C-SW | Three Phase, 575V, 60 Hz |
| ULOC-044G-Q-D-SA | Three Phase, 575V, 60 Hz |
| ULOC-044G-Q-D-SB | Three Phase, 575V, 60 Hz |
| ULOC-011D-Q-B-SW | Three Phase, 575V, 60 Hz |
| ULOC-011D-W-A-SA | No motor |
| ULOC-011D-W-A-SB | No motor |
| ULOC-011D-W-A-SW | No motor |
| ULOC-011D-W-B-SA | No motor |
| ULOC-011D-W-B-SB | No motor |
| ULOC-044G-Q-D-SW | Three Phase, 575V, 60 Hz |
| ULOC-044G-W-C-SA | No motor |
| ULOC-044G-W-C-SB | No motor |
| ULOC-044G-W-C-SW | No motor |
| ULOC-044G-W-D-SA | No motor |
| ULOC-044G-W-D-SB | No motor |
| ULOC-011D-W-B-SW | No motor |
| ULOC-011E-M-C-SA | Three Phase, 190/380V 50 Hz, 208-230/460V 60 Hz |
| ULOC-011E-M-C-SB | Three Phase, 190/380V 50 Hz, 208-230/460V 60 Hz |
| ULOC-011E-M-C-SW | Three Phase, 190/380V 50 Hz, 208-230/460V 60 Hz |
| ULOC-011E-M-D-SA | Three Phase, 190/380V 50 Hz, 208-230/460V 60 Hz |
| ULOC-011E-M-D-SB | Three Phase, 190/380V 50 Hz, 208-230/460V 60 Hz |
| ULOC-044G-W-D-SW | No motor |
| ULOC-011E-M-D-SW | Three Phase, 190/380V 50 Hz, 208-230/460V 60 Hz |
| ULOC-011E-Q-C-SA | Three Phase, 575V, 60 Hz |
| ULOC-011E-Q-C-SB | Three Phase, 575V, 60 Hz |
| ULOC-011E-Q-C-SW | Three Phase, 575V, 60 Hz |
| ULOC-011E-Q-D-SA | Three Phase, 575V, 60 Hz |
| ULOC-011E-Q-D-SB | Three Phase, 575V, 60 Hz |
| ULOC-011E-Q-D-SW | Three Phase, 575V, 60 Hz |
| ULOC-011E-W-C-SA | No motor |
| ULOC-011E-W-C-SB | No motor |
| ULOC-011E-W-C-SW | No motor |
| ULOC-011E-W-D-SA | No motor |
| ULOC-011E-W-D-SB | No motor |
| ULOC-011E-W-D-SW | No motor |
| ULOC-016E-M-A-SA | Three Phase, 190/380V 50 Hz, 208-230/460V 60 Hz |
| ULOC-016E-M-A-SB | Three Phase, 190/380V 50 Hz, 208-230/460V 60 Hz |
| ULOC-016E-M-A-SW | Three Phase, 190/380V 50 Hz, 208-230/460V 60 Hz |
| ULOC-016E-M-B-SA | Three Phase, 190/380V 50 Hz, 208-230/460V 60 Hz |
| ULOC-016E-M-B-SB | Three Phase, 190/380V 50 Hz, 208-230/460V 60 Hz |
| ULOC-016E-M-B-SW | Three Phase, 190/380V 50 Hz, 208-230/460V 60 Hz |
| ULOC-016E-Q-A-SA | Three Phase, 575V, 60 Hz |
| ULOC-016E-Q-A-SB | Three Phase, 575V, 60 Hz |
| ULOC-016E-Q-A-SW | Three Phase, 575V, 60 Hz |
| ULOC-016E-Q-B-SA | Three Phase, 575V, 60 Hz |
| ULOC-016E-Q-B-SB | Three Phase, 575V, 60 Hz |
| ULOC-016E-Q-B-SW | Three Phase, 575V, 60 Hz |
| ULOC-016E-W-A-SA | No motor |
| ULOC-016E-W-A-SB | No motor |
| ULOC-016E-W-A-SW | No motor |
| ULOC-016E-W-B-SA | No motor |
| ULOC-016E-W-B-SB | No motor |
| ULOC-016E-W-B-SW | No motor |
| ULOC-016E-M-C-SA | Three Phase, 190/380V 50 Hz, 208-230/460V 60 Hz |
| ULOC-016E-M-C-SB | Three Phase, 190/380V 50 Hz, 208-230/460V 60 Hz |
| ULOC-016E-M-C-SW | Three Phase, 190/380V 50 Hz, 208-230/460V 60 Hz |
| ULOC-016E-M-D-SA | Three Phase, 190/380V 50 Hz, 208-230/460V 60 Hz |
| ULOC-016E-M-D-SB | Three Phase, 190/380V 50 Hz, 208-230/460V 60 Hz |
| ULOC-016E-M-D-SW | Three Phase, 190/380V 50 Hz, 208-230/460V 60 Hz |
| ULOC-016E-Q-C-SA | Three Phase, 575V, 60 Hz |
| ULOC-016E-Q-C-SB | Three Phase, 575V, 60 Hz |
| ULOC-016E-Q-C-SW | Three Phase, 575V, 60 Hz |
| ULOC-016E-Q-D-SA | Three Phase, 575V, 60 Hz |
| ULOC-016E-Q-D-SB | Three Phase, 575V, 60 Hz |
| ULOC-016E-Q-D-SW | Three Phase, 575V, 60 Hz |
| ULOC-016E-W-C-SA | No motor |
| ULOC-016E-W-C-SB | No motor |
| ULOC-016E-W-C-SW | No motor |
| ULOC-016E-W-D-SA | No motor |
| ULOC-016E-W-D-SB | No motor |
| ULOC-016E-W-D-SW | No motor |
| ULOC-023F-M-C-SA | Three Phase, 190/380V 50 Hz, 208-230/460V 60 Hz |
| ULOC-023F-M-C-SB | Three Phase, 190/380V 50 Hz, 208-230/460V 60 Hz |
| ULOC-023F-M-C-SW | Three Phase, 190/380V 50 Hz, 208-230/460V 60 Hz |
| ULOC-023F-M-D-SA | Three Phase, 190/380V 50 Hz, 208-230/460V 60 Hz |
| ULOC-023F-M-D-SB | Three Phase, 190/380V 50 Hz, 208-230/460V 60 Hz |
| ULOC-007D-M-B-SW | Three Phase, 190/380V 50 Hz, 208-230/460V 60 Hz |
| ULOC-007D-Q-A-SA | Three Phase, 575V, 60 Hz |
| ULOC-007D-Q-A-SB | Three Phase, 575V, 60 Hz |
| ULOC-007D-Q-A-SW | Three Phase, 575V, 60 Hz |
| ULOC-007D-Q-B-SA | Three Phase, 575V, 60 Hz |
| ULOC-007D-Q-B-SB | Three Phase, 575V, 60 Hz |
| ULOC-023F-M-D-SW | Three Phase, 190/380V 50 Hz, 208-230/460V 60 Hz |
| ULOC-023F-Q-C-SA | Three Phase, 575V, 60 Hz |
| ULOC-023F-Q-C-SB | Three Phase, 575V, 60 Hz |
| ULOC-023F-Q-C-SW | Three Phase, 575V, 60 Hz |
| ULOC-023F-Q-D-SA | Three Phase, 575V, 60 Hz |
| ULOC-023F-Q-D-SB | Three Phase, 575V, 60 Hz |
| ULOC-023F-W-D-SW | No motor |
| ULOC-033G-M-C-SA | Three Phase, 190/380V 50 Hz, 208-230/460V 60 Hz |
| ULOC-033G-M-C-SB | Three Phase, 190/380V 50 Hz, 208-230/460V 60 Hz |
| ULOC-033G-M-C-SW | Three Phase, 190/380V 50 Hz, 208-230/460V 60 Hz |
| ULOC-033G-M-D-SA | Three Phase, 190/380V 50 Hz, 208-230/460V 60 Hz |
| ULOC-033G-M-D-SB | Three Phase, 190/380V 50 Hz, 208-230/460V 60 Hz |
------------------------
Nhà phân phối sản phẩm Parker tại Việt Nam - Parker Vietnam Distributor
CÔNG TY CỔ PHẦN KỸ THUẬT VÀ THƯƠNG MẠI THIẾT BỊ CÔNG NGHIỆP NTD
Adress: No. 28, Alley 36 Co Linh Street, Group 7, Long Bien Ward, Long Bien District, Hanoi City, Vietnam.
Hotline: 0971961212
Mail: sales@ntd-automation.com






