M5VS-AA-R SIGNAL TRANSMITTER
Liên hệ
Còn hàng
SIGNAL TRANSMITTER
Functions & Features
• Converts a DC input into an isolated DC signal
• High-density mounting
• Power LED
MODEL: M5VS-[1][2]-[3][4]
ORDERING INFORMATION
• Code number: M5VS-[1][2]-[3][4]
Specify a code from below for each of [1] through [4].
(e.g. M5VS-4W4W-R/K/Q)
• Special input and output ranges (For codes Z, 0, 01 & 02)
• Specify the specification for option code /Q
(e.g. /C01/V01/S01)
[1] INPUT
Current
A: 4 – 20 mA DC (Input resistance 249 Ω)
A1: 4 – 20 mA DC (Input resistance 49.9 Ω)
B: 2 – 10 mA DC (Input resistance 499 Ω)
C: 1 – 5 mA DC (Input resistance 1000 Ω)
D: 0 – 20 mA DC (Input resistance 49.9 Ω)
E: 0 – 16 mA DC (Input resistance 61.9 Ω)
F: 0 – 10 mA DC (Input resistance 100 Ω)
G: 0 – 1 mA DC (Input resistance 1000 Ω)
H: 10 – 50 mA DC (Input resistance 20 Ω)
Z: Specify current (See INPUT SPECIFICATIONS)
Voltage
3: 0 – 1 V DC (Input resistance 1 MΩ min.)
4: 0 – 10 V DC (Input resistance 1 MΩ min.)
5: 0 – 5 V DC (Input resistance 1 MΩ min.)
6: 1 – 5 V DC (Input resistance 1 MΩ min.)
4W: -10 – +10 V DC (Input resistance 1 MΩ min.)
5W: -5 – +5 V DC (Input resistance 1 MΩ min.)
0: Specify voltage (See INPUT SPECIFICATIONS)
(CE not available)
01: Specify voltage (See INPUT SPECIFICATIONS)
(Choose 01 for CE. Power suffix code R only.)
02: Specify voltage (See INPUT SPECIFICATIONS)
(CE not available)
[2] OUTPUT
Current
A: 4 – 20 mA DC (Load resistance 550 Ω max.)
D: 0 – 20 mA DC (Load resistance 550 Ω max.)
Z: Specify current (See OUTPUT SPECIFICATIONS)
Voltage
1: 0 – 10 mV DC (Load resistance 100 kΩ min.)
(CE not available)
2: 0 – 100 mV DC (Load resistance 100 kΩ min.)
(CE not available)
3: 0 – 1 V DC (Load resistance 100 Ω min.)
4: 0 – 10 V DC (Load resistance 1000 Ω min.)
5: 0 – 5 V DC (Load resistance 500 Ω min.)
6: 1 – 5 V DC (Load resistance 500 Ω min.)
1W: -10 – +10 mV DC (Load resistance 100 kΩ min.)
(CE not available)
2W: -100 – +100 mV DC (Load resistance 100 kΩ min.)
(CE not available)
3W: -1 – +1 V DC (Load resistance 800 Ω min.)
4W: -10 – +10 V DC (Load resistance 8000 Ω min.)
5W: -5 – +5 V DC (Load resistance 4000 Ω min.)
0: Specify voltage (See OUTPUT SPECIFICATIONS)
01: Specify voltage (See OUTPUT SPECIFICATIONS)
(CE not available)
[3] POWER INPUT
AC Power
M: 85 – 264 V AC (Operational voltage range 85 – 264 V,
47 – 66 Hz)
(CE not available)
DC Power
R: 24 V DC
(Operational voltage range 24 V ±10 %, ripple 10 %p-p max.)
[4] OPTIONS (multiple selections)
Response Time (0 – 90 %)
blank: Standard (≤ 0.5 sec.)
/K: Fast Response (Approx. 25 msec.)
/F: Fast Response (≤ 1 msec.)
Other Options
blank: none
/Q: Option other than the above (specify the specification)
SPECIFICATIONS OF OPTION: Q (multiple selections)
COATING (For the detail, refer to M-System's web site.)
/C01: Silicone coating
/C02: Polyurethane coating
/C03: Rubber coating
ADJUSTMENT
/V01: Multi-turn fine adjustment
/VN: Sealed adjustment holes
TERMINAL SCREW MATERIAL
/S01: Stainless steel
GENERAL SPECIFICATIONS
Construction: Terminal block
Connection: M3.5 screw terminals (torque 0.8 N·m)
Screw terminal: Nickel-plated steel (standard) or stainless steel
Housing material: Flame-resistant resin (black)
Isolation: Input to output to power
Overrange output: Approx. -10 to +110 % at 1 – 5 V
Zero adjustment: -2 to +2 % (front)
(±1 % with the input suffix codes 4W and 5W selected)
Span adjustment: 98 to 102 % (front)
(99 to 101 % with the input suffix codes 4W and 5W selected.)
Power LED: Green LED turns on when the power is supplied.
INPUT SPECIFICATIONS
■ DC Current: Input resistor incorporated
Specify input resistance value among followings for code Z.
20Ω, 49.9Ω, 61.9Ω, 100Ω, 249Ω, 499Ω, 1000Ω
(0.125 W ≥ [Input current]2 × R)
■ DC Voltage
Input resistance: 1 MΩ min. (10 kΩ min. at power loss)
•Input code 0 (Not CE)
Voltage range: -300 – +300 V DC
Minimum span: 100 mV
Offset: Max. 1.5 times span
•Input code 01 (CE)
Voltage range: -70 – +70 V DC
Minimum span: 100 mV
Offset: Max. 1.5 times span
•Input code 02 (Not CE)
Voltage range: 0 – 500 V DC
Minimum span: 200 V
Offset: Max. 1.5 times span
Input at 100%: min. 300 V
OUTPUT SPECIFICATIONS
■ DC Current: 0 – 20 mA DC
Minimum span: 1 mA
Offset: Max. 1.5 times span
Load resistance: Output drive 11 V max.
■ DC Voltage
•Output code 0 (CE)
Voltage range: -10 – +10 V DC
Minimum span: 1 V
Offset: Max. 1.5 times span
Load resistance: Output drive 10 mA max.; at ≥1 V
Max. 1.25 mA output drive for negative voltage
•Output code 01 (Not CE)
Voltage range: -1 – +1 V DC
Minimum span: 10 mV
Offset: Max. 1.5 times span
Load resistance: Min. 100 kΩ
Min. 1 MΩ for negative voltage
INSTALLATION
Power Consumption
•AC:
Approx. 2 VA at 100 V
Approx. 3 VA at 200 V
Approx. 3 VA at 264 V
•DC: Approx. 2 W
Operating temperature: -5 to +55°C (23 to 131°F)
Operating humidity: 0 to 90 %RH (non-condensing)
Mounting: DIN rail
Weight: 80 g (2.8 oz)
PERFORMANCE in percentage of span
Accuracy: ±0.1 %
±0.2 % for the input code 02
Temp. coefficient: ±0.015 %/°C (±0.008 %/°F)
±0.02 %/°C (±0.01 %/°F) at input <1 V and output <5 mA
±0.03 %/°C (±0.02 %/°F) for the input code 02
Line voltage effect: ±0.1 % over voltage range
Insulation resistance: ≥ 100 MΩ with 500 V DC
Dielectric strength (input to output to power to ground)
DC powered: 2000 V AC @1 minute
AC powered: 1500 V AC @1 minute
STANDARDS & APPROVALS
EU conformity:
EMC Directive
EMI EN 61000-6-4
EMS EN 61000-6-2
RoHS Directive
EN 50581
FRONT VIEW
EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm (inch)
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM
M-System Vietnam
Functions & Features
• Converts a DC input into an isolated DC signal
• High-density mounting
• Power LED
MODEL: M5VS-[1][2]-[3][4]
ORDERING INFORMATION
• Code number: M5VS-[1][2]-[3][4]
Specify a code from below for each of [1] through [4].
(e.g. M5VS-4W4W-R/K/Q)
• Special input and output ranges (For codes Z, 0, 01 & 02)
• Specify the specification for option code /Q
(e.g. /C01/V01/S01)
[1] INPUT
Current
A: 4 – 20 mA DC (Input resistance 249 Ω)
A1: 4 – 20 mA DC (Input resistance 49.9 Ω)
B: 2 – 10 mA DC (Input resistance 499 Ω)
C: 1 – 5 mA DC (Input resistance 1000 Ω)
D: 0 – 20 mA DC (Input resistance 49.9 Ω)
E: 0 – 16 mA DC (Input resistance 61.9 Ω)
F: 0 – 10 mA DC (Input resistance 100 Ω)
G: 0 – 1 mA DC (Input resistance 1000 Ω)
H: 10 – 50 mA DC (Input resistance 20 Ω)
Z: Specify current (See INPUT SPECIFICATIONS)
Voltage
3: 0 – 1 V DC (Input resistance 1 MΩ min.)
4: 0 – 10 V DC (Input resistance 1 MΩ min.)
5: 0 – 5 V DC (Input resistance 1 MΩ min.)
6: 1 – 5 V DC (Input resistance 1 MΩ min.)
4W: -10 – +10 V DC (Input resistance 1 MΩ min.)
5W: -5 – +5 V DC (Input resistance 1 MΩ min.)
0: Specify voltage (See INPUT SPECIFICATIONS)
(CE not available)
01: Specify voltage (See INPUT SPECIFICATIONS)
(Choose 01 for CE. Power suffix code R only.)
02: Specify voltage (See INPUT SPECIFICATIONS)
(CE not available)
[2] OUTPUT
Current
A: 4 – 20 mA DC (Load resistance 550 Ω max.)
D: 0 – 20 mA DC (Load resistance 550 Ω max.)
Z: Specify current (See OUTPUT SPECIFICATIONS)
Voltage
1: 0 – 10 mV DC (Load resistance 100 kΩ min.)
(CE not available)
2: 0 – 100 mV DC (Load resistance 100 kΩ min.)
(CE not available)
3: 0 – 1 V DC (Load resistance 100 Ω min.)
4: 0 – 10 V DC (Load resistance 1000 Ω min.)
5: 0 – 5 V DC (Load resistance 500 Ω min.)
6: 1 – 5 V DC (Load resistance 500 Ω min.)
1W: -10 – +10 mV DC (Load resistance 100 kΩ min.)
(CE not available)
2W: -100 – +100 mV DC (Load resistance 100 kΩ min.)
(CE not available)
3W: -1 – +1 V DC (Load resistance 800 Ω min.)
4W: -10 – +10 V DC (Load resistance 8000 Ω min.)
5W: -5 – +5 V DC (Load resistance 4000 Ω min.)
0: Specify voltage (See OUTPUT SPECIFICATIONS)
01: Specify voltage (See OUTPUT SPECIFICATIONS)
(CE not available)
[3] POWER INPUT
AC Power
M: 85 – 264 V AC (Operational voltage range 85 – 264 V,
47 – 66 Hz)
(CE not available)
DC Power
R: 24 V DC
(Operational voltage range 24 V ±10 %, ripple 10 %p-p max.)
[4] OPTIONS (multiple selections)
Response Time (0 – 90 %)
blank: Standard (≤ 0.5 sec.)
/K: Fast Response (Approx. 25 msec.)
/F: Fast Response (≤ 1 msec.)
Other Options
blank: none
/Q: Option other than the above (specify the specification)
SPECIFICATIONS OF OPTION: Q (multiple selections)
COATING (For the detail, refer to M-System's web site.)
/C01: Silicone coating
/C02: Polyurethane coating
/C03: Rubber coating
ADJUSTMENT
/V01: Multi-turn fine adjustment
/VN: Sealed adjustment holes
TERMINAL SCREW MATERIAL
/S01: Stainless steel
GENERAL SPECIFICATIONS
Construction: Terminal block
Connection: M3.5 screw terminals (torque 0.8 N·m)
Screw terminal: Nickel-plated steel (standard) or stainless steel
Housing material: Flame-resistant resin (black)
Isolation: Input to output to power
Overrange output: Approx. -10 to +110 % at 1 – 5 V
Zero adjustment: -2 to +2 % (front)
(±1 % with the input suffix codes 4W and 5W selected)
Span adjustment: 98 to 102 % (front)
(99 to 101 % with the input suffix codes 4W and 5W selected.)
Power LED: Green LED turns on when the power is supplied.
INPUT SPECIFICATIONS
■ DC Current: Input resistor incorporated
Specify input resistance value among followings for code Z.
20Ω, 49.9Ω, 61.9Ω, 100Ω, 249Ω, 499Ω, 1000Ω
(0.125 W ≥ [Input current]2 × R)
■ DC Voltage
Input resistance: 1 MΩ min. (10 kΩ min. at power loss)
•Input code 0 (Not CE)
Voltage range: -300 – +300 V DC
Minimum span: 100 mV
Offset: Max. 1.5 times span
•Input code 01 (CE)
Voltage range: -70 – +70 V DC
Minimum span: 100 mV
Offset: Max. 1.5 times span
•Input code 02 (Not CE)
Voltage range: 0 – 500 V DC
Minimum span: 200 V
Offset: Max. 1.5 times span
Input at 100%: min. 300 V
OUTPUT SPECIFICATIONS
■ DC Current: 0 – 20 mA DC
Minimum span: 1 mA
Offset: Max. 1.5 times span
Load resistance: Output drive 11 V max.
■ DC Voltage
•Output code 0 (CE)
Voltage range: -10 – +10 V DC
Minimum span: 1 V
Offset: Max. 1.5 times span
Load resistance: Output drive 10 mA max.; at ≥1 V
Max. 1.25 mA output drive for negative voltage
•Output code 01 (Not CE)
Voltage range: -1 – +1 V DC
Minimum span: 10 mV
Offset: Max. 1.5 times span
Load resistance: Min. 100 kΩ
Min. 1 MΩ for negative voltage
INSTALLATION
Power Consumption
•AC:
Approx. 2 VA at 100 V
Approx. 3 VA at 200 V
Approx. 3 VA at 264 V
•DC: Approx. 2 W
Operating temperature: -5 to +55°C (23 to 131°F)
Operating humidity: 0 to 90 %RH (non-condensing)
Mounting: DIN rail
Weight: 80 g (2.8 oz)
PERFORMANCE in percentage of span
Accuracy: ±0.1 %
±0.2 % for the input code 02
Temp. coefficient: ±0.015 %/°C (±0.008 %/°F)
±0.02 %/°C (±0.01 %/°F) at input <1 V and output <5 mA
±0.03 %/°C (±0.02 %/°F) for the input code 02
Line voltage effect: ±0.1 % over voltage range
Insulation resistance: ≥ 100 MΩ with 500 V DC
Dielectric strength (input to output to power to ground)
DC powered: 2000 V AC @1 minute
AC powered: 1500 V AC @1 minute
STANDARDS & APPROVALS
EU conformity:
EMC Directive
EMI EN 61000-6-4
EMS EN 61000-6-2
RoHS Directive
EN 50581
FRONT VIEW
EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm (inch)
SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM
M-System Vietnam
Email: sales@m-system.com.vn
| Model | Input | Output | Power Supply |
| 0...1 A (AC) | 0...10 Vdc | 85...264 Vac | |
| 0...1 A (AC) | 4...20 mA | 85...264 Vac | |
| 0...5 A (AC) | 0...10 Vdc | 85...264 Vac | |
| 0...5 A (AC) | 4...20 mA | 85...264 Vac | |
| 4...20 mA | 0...10 Vdc | 24 Vdc | |
| 4...20 mA | 0...10 Vdc | 24 Vdc | |
| 4...20 mA | 1...5 Vdc | 24 Vdc | |
| 4...20 mA | 1...5 Vdc | 24 Vdc | |
| 4...20 mA | 4...20 mA | 24 Vdc | |
| 4...20 mA | 4...20 mA | 24 Vdc | |
| 4...20 mA | 0...20 mA | 24 Vdc | |
| 4...20 mA | 0...20 mA | 24 Vdc | |
| Potentiometer 0,1...10 kOhm | 0...10 Vdc | 24 Vdc | |
| Potentiometer 0,1...10 kOhm | 0...10 Vdc | 24 Vdc | |
| Potentiometer 0,1...10 kOhm | 1...5 Vdc | 24 Vdc | |
| Potentiometer 0,1...10 kOhm | 1...5 Vdc | 24 Vdc | |
| Potentiometer 0,1...10 kOhm | 4...20 mA | 24 Vdc | |
| Potentiometer 0,1...10 kOhm | 4...20 mA | 24 Vdc | |
| Potentiometer 0,1...10 kOhm | 0...20 mA | 24 Vdc | |
| Potentiometer 0,1...10 kOhm | 0...20 mA | 24 Vdc | |
| 0...10 mVdc | 0...10 Vdc | 24 Vdc | |
| 0...10 mVdc | 0...10 Vdc | 24 Vdc | |
| 0...50 mVdc | 0...10 Vdc | 24 Vdc | |
| 0...50 mVdc | 0...10 Vdc | 24 Vdc | |
| 0...50 mVdc | 1...5 Vdc | 24 Vdc | |
| 0...50 mVdc | 1...5 Vdc | 24 Vdc | |
| 0...50 mVdc | 0...20 mA | 24 Vdc | |
| 0...50 mVdc | 0...20 mA | 24 Vdc | |
| 0...10 mVdc | 1...5 Vdc | 24 Vdc | |
| 0...10 mVdc | 1...5 Vdc | 24 Vdc | |
| 0...10 mVdc | 0...20 mA | 24 Vdc | |
| 0...10 mVdc | 0...20 mA | 24 Vdc | |
| 0...100 µA | 0...10 Vdc | 24 Vdc | |
| 0...100 µA | 0...10 Vdc | 24 Vdc | |
| 0...100 µA | 1...5 Vdc | 24 Vdc | |
| 0...100 µA | 1...5 Vdc | 24 Vdc | |
| 0...100 µA | 0...20 mA | 24 Vdc | |
| 0...100 µA | 0...20 mA | 24 Vdc | |
| Open Collector, 0...100 kHz | 0...10 Vdc | 24 Vdc | |
| Open Collector, 0...100 kHz | 1...5 Vdc | 24 Vdc | |
| Open Collector, 0...100 kHz | 4...20 mA | 24 Vdc | |
| Relay, 0...30 Hz | 0...10 Vdc | 24 Vdc | |
| Relay, 0...30 Hz | 1...5 Vdc | 24 Vdc | |
| Relay, 0...30 Hz | 4...20 mA | 24 Vdc | |
| Voltage puls fix 5V, 0...100 kHz | 0...10 Vdc | 24 Vdc | |
| Voltage puls fix 5V, 0...100 kHz | 1...5 Vdc | 24 Vdc | |
| Voltage puls fix 5V, 0...100 kHz | 4...20 mA | 24 Vdc | |
| Voltage puls fix 12/24V, 0...100 kHz | 0...10 Vdc | 24 Vdc | |
| Voltage puls fix 12/24V, 0...100 kHz | 1...5 Vdc | 24 Vdc | |
| Voltage puls fix 12/24V, 0...100 kHz | 4...20 mA | 24 Vdc | |
| RTD (PT100) | 0...10 Vdc | 24 Vdc | |
| RTD (PT100) | 0...10 Vdc | 24 Vdc | |
| RTD (PT100) | 1...5 Vdc | 24 Vdc | |
| RTD (PT100) | 1...5 Vdc | 24 Vdc | |
| RTD (PT100) | 4...20 mA | 24 Vdc | |
| RTD (PT100) | 4...20 mA | 24 Vdc | |
| RTD (PT100) | 0...20 mA | 24 Vdc | |
| RTD (PT100) | 0...20 mA | 24 Vdc | |
| Thermocouple K | 0...10 Vdc | 24 Vdc | |
| Thermocouple K | 0...10 Vdc | 24 Vdc | |
| Thermocouple K | 1...5 Vdc | 24 Vdc | |
| Thermocouple K | 1...5 Vdc | 24 Vdc | |
| Thermocouple K | 4...20 mA | 24 Vdc | |
| Thermocouple K | 4...20 mA | 24 Vdc | |
| Thermocouple K | 0...20 mA | 24 Vdc | |
| Thermocouple K | 0...20 mA | 24 Vdc | |
| Thermocouple J | 0...10 Vdc | 24 Vdc | |
| Thermocouple J | 0...10 Vdc | 24 Vdc | |
| Thermocouple J | 1...5 Vdc | 24 Vdc | |
| Thermocouple J | 1...5 Vdc | 24 Vdc | |
| Thermocouple J | 4...20 mA | 24 Vdc | |
| Thermocouple J | 4...20 mA | 24 Vdc | |
| Thermocouple J | 0...20 mA | 24 Vdc | |
| Thermocouple J | 0...20 mA | 24 Vdc | |
| Thermocouple T | 0...10 Vdc | 24 Vdc | |
| Thermocouple T | 0...10 Vdc | 24 Vdc | |
| Thermocouple T | 1...5 Vdc | 24 Vdc | |
| Thermocouple T | 1...5 Vdc | 24 Vdc | |
| Thermocouple T | 4...20 mA | 24 Vdc | |
| Thermocouple T | 4...20 mA | 24 Vdc | |
| Thermocouple T | 0...20 mA | 24 Vdc | |
| Thermocouple T | 0...20 mA | 24 Vdc | |
| 0...10 Vdc | 0...10 Vdc | 24 Vdc | |
| 0...10 Vdc | 1...5 Vdc | 24 Vdc | |
| 0...10 Vdc | 4...20 mA | 24 Vdc | |
| 1...5 Vdc | 0...10 Vdc | 24 Vdc | |
| 1...5 Vdc | 1...5 Vdc | 24 Vdc | |
| 1...5 Vdc | 4...20 mA | 24 Vdc | |
| 4...20 mA | 0...10 Vdc | 24 Vdc | |
| 4...20 mA | 1...5 Vdc | 24 Vdc | |
| 4...20 mA | 4...20 mA | 24 Vdc | |
| 0...20 mA | 0...10 Vdc | 24 Vdc | |
| 0...20 mA | 1...5 Vdc | 24 Vdc | |
| 0...20 mA | 4...20 mA | 24 Vdc | |
| 0...10 Vdc | 0...10 Vdc | 24 Vdc | |
| 0...10 Vdc | 0...10 Vdc | 24 Vdc | |
| 0...10 Vdc | 0...10 Vdc | 24 Vdc | |
| 0...10 Vdc | 1...5 Vdc | 24 Vdc | |
| 0...10 Vdc | 1...5 Vdc | 24 Vdc | |
| 0...10 Vdc | 1...5 Vdc | 24 Vdc | |
| 0...10 Vdc | 4...20 mA | 24 Vdc | |
| 0...10 Vdc | 4...20 mA | 24 Vdc | |
| 0...10 Vdc | 4...20 mA | 24 Vdc | |
| 0...10 Vdc | 0...20 mA | 24 Vdc | |
| 0...10 Vdc | 0...20 mA | 24 Vdc | |
| 0...10 Vdc | 0...20 mA | 24 Vdc | |
| 1...5 Vdc | 0...10 Vdc | 24 Vdc | |
| 1...5 Vdc | 0...10 Vdc | 24 Vdc | |
| 1...5 Vdc | 0...10 Vdc | 24 Vdc | |
| 1...5 Vdc | 1...5 Vdc | 24 Vdc | |
| 1...5 Vdc | 1...5 Vdc | 24 Vdc | |
| 1...5 Vdc | 1...5 Vdc | 24 Vdc | |
| 1...5 Vdc | 4...20 mA | 24 Vdc | |
| 1...5 Vdc | 4...20 mA | 24 Vdc | |
| 1...5 Vdc | 4...20 mA | 24 Vdc | |
| 1...5 Vdc | 0...20 mA | 24 Vdc | |
| 1...5 Vdc | 0...20 mA | 24 Vdc | |
| 1...5 Vdc | 0...20 mA | 24 Vdc | |
| 4...20 mA / 50 Ohm | 0...10 Vdc | 24 Vdc | |
| 4...20 mA / 50 Ohm | 0...10 Vdc | 24 Vdc | |
| 4...20 mA / 50 Ohm | 0...10 Vdc | 24 Vdc | |
| 4...20 mA / 50 Ohm | 1...5 Vdc | 24 Vdc | |
| 4...20 mA / 50 Ohm | 1...5 Vdc | 24 Vdc | |
| 4...20 mA / 50 Ohm | 1...5 Vdc | 24 Vdc | |
| 4...20 mA / 50 Ohm | 4...20 mA | 24 Vdc | |
| 4...20 mA / 50 Ohm | 4...20 mA | 24 Vdc | |
| 4...20 mA / 50 Ohm | 4...20 mA | 24 Vdc | |
| 4...20 mA / 50 Ohm | 0...20 mA | 24 Vdc | |
| 4...20 mA / 50 Ohm | 0...20 mA | 24 Vdc | |
| 4...20 mA / 50 Ohm | 0...20 mA | 24 Vdc | |
| 4...20 mA | 0...10 Vdc | 24 Vdc | |
| 4...20 mA | 0...10 Vdc | 24 Vdc | |
| 4...20 mA | 0...10 Vdc | 24 Vdc | |
| 4...20 mA | 1...5 Vdc | 24 Vdc | |
| 4...20 mA | 1...5 Vdc | 24 Vdc | |
| 4...20 mA | 1...5 Vdc | 24 Vdc | |
| 4...20 mA | 4...20 mA | 24 Vdc | |
| 4...20 mA | 4...20 mA | 24 Vdc | |
| 4...20 mA | 4...20 mA | 24 Vdc | |
| 4...20 mA | 0...20 mA | 24 Vdc | |
| 4...20 mA | 0...20 mA | 24 Vdc | |
| 4...20 mA | 0...20 mA | 24 Vdc | |
| 0...20 mA | 0...10 Vdc | 24 Vdc | |
| 0...20 mA | 0...10 Vdc | 24 Vdc | |
| 0...20 mA | 0...10 Vdc | 24 Vdc | |
| 0...20 mA | 1...5 Vdc | 24 Vdc | |
| 0...20 mA | 1...5 Vdc | 24 Vdc | |
| 0...20 mA | 1...5 Vdc | 24 Vdc | |
| 0...20 mA | 4...20 mA | 24 Vdc | |
| 0...20 mA | 4...20 mA | 24 Vdc | |
| 0...20 mA | 4...20 mA | 24 Vdc | |
| 0...20 mA | 0...20 mA | 24 Vdc | |
| 0...20 mA | 0...20 mA | 24 Vdc | |
| 0...20 mA | 0...20 mA | 24 Vdc | |
| 4...20 mA | 4...20 mA / 0...10 Vdc | 24 Vdc | |
| 4...20 mA | 4...20 mA / 0...10 Vdc | 24 Vdc | |
| 4...20 mA | 4...20 mA / 1...5 Vdc | 24 Vdc | |
| 4...20 mA | 4...20 mA / 1...5 Vdc | 24 Vdc | |
| W5DY-AA-R | 4...20 mA | 4...20 mA / 4...20 mA | 24 Vdc |
| W5DY-AA-R/K | 4...20 mA | 4...20 mA / 4...20 mA | 24 Vdc |
| W5DY-AD-R | 4...20 mA | 4...20 mA / 0...20 mA | 24 Vdc |
| W5DY-AD-R/K | 4...20 mA | 4...20 mA / 0...20 mA | 24 Vdc |
| W5FV-4-R | mA / Vdc (Field) | 0...10 Vdc | 24 Vdc |
| W5FV-6-R | mA / Vdc (Field) | 1...5 Vdc | 24 Vdc |
| W5FV-A-R | mA / Vdc (Field) | 4...20 mA | 24 Vdc |
| W5FV-D-R | mA / Vdc (Field) | 0...20 mA | 24 Vdc |
| W5MS-44-R | Potentiometer 0,1...10 kOhm | 0...10 Vdc / 0...10 Vdc | 24 Vdc |
| W5MS-44-R/K | Potentiometer 0,1...10 kOhm | 0...10 Vdc / 0...10 Vdc | 24 Vdc |
| W5MS-46-R | Potentiometer 0,1...10 kOhm | 0...10 Vdc / 1...5 Vdc | 24 Vdc |
| W5MS-46-R/K | Potentiometer 0,1...10 kOhm | 0...10 Vdc / 1...5 Vdc | 24 Vdc |
| W5MS-4A-R | Potentiometer 0,1...10 kOhm | 0...10 Vdc / 4...20 mA | 24 Vdc |
| W5MS-4A-R/K | Potentiometer 0,1...10 kOhm | 0...10 Vdc / 4...20 mA | 24 Vdc |
| W5MS-4D-R | Potentiometer 0,1...10 kOhm | 0...10 Vdc / 0...20 mA | 24 Vdc |
| W5MS-4D-R/K | Potentiometer 0,1...10 kOhm | 0...10 Vdc / 0...20 mA | 24 Vdc |
| W5MS-64-R | Potentiometer 0,1...10 kOhm | 1...5 Vdc / 0...10 Vdc | 24 Vdc |
| W5MS-64-R/K | Potentiometer 0,1...10 kOhm | 1...5 Vdc / 0...10 Vdc | 24 Vdc |
| W5MS-66-R | Potentiometer 0,1...10 kOhm | 1...5 Vdc / 1...5 Vdc | 24 Vdc |
| W5MS-66-R/K | Potentiometer 0,1...10 kOhm | 1...5 Vdc / 1...5 Vdc | 24 Vdc |
| W5MS-6A-R | Potentiometer 0,1...10 kOhm | 1...5 Vdc / 4...20 mA | 24 Vdc |
| W5MS-6A-R/K | Potentiometer 0,1...10 kOhm | 1...5 Vdc / 4...20 mA | 24 Vdc |
| W5MS-6D-R | Potentiometer 0,1...10 kOhm | 1...5 Vdc / 0...20 mA | 24 Vdc |
| W5MS-6D-R/K | Potentiometer 0,1...10 kOhm | 1...5 Vdc / 0...20 mA | 24 Vdc |
| W5MS-A4-R | Potentiometer 0,1...10 kOhm | 4...20 mA / 0...10 Vdc | 24 Vdc |
| W5MS-A4-R/K | Potentiometer 0,1...10 kOhm | 4...20 mA / 0...10 Vdc | 24 Vdc |
| W5MS-A6-R | Potentiometer 0,1...10 kOhm | 4...20 mA / 1...5 Vdc | 24 Vdc |
| W5MS-A6-R/K | Potentiometer 0,1...10 kOhm | 4...20 mA / 1...5 Vdc | 24 Vdc |
| W5MS-AA-R | Potentiometer 0,1...10 kOhm | 4...20 mA / 4...20 mA | 24 Vdc |
| W5MS-AA-R/K | Potentiometer 0,1...10 kOhm | 4...20 mA / 4...20 mA | 24 Vdc |
| W5MS-AD-R | Potentiometer 0,1...10 kOhm | 4...20 mA / 0...20 mA | 24 Vdc |
| W5MS-AD-R/K | Potentiometer 0,1...10 kOhm | 4...20 mA / 0...20 mA | 24 Vdc |
| W5MS-D4-R | Potentiometer 0,1...10 kOhm | 0...20 mA / 0...10 Vdc | 24 Vdc |
| W5MS-D4-R/K | Potentiometer 0,1...10 kOhm | 0...20 mA / 0...10 Vdc | 24 Vdc |
| W5MS-D6-R | Potentiometer 0,1...10 kOhm | 0...20 mA / 1...5 Vdc | 24 Vdc |
| W5MS-D6-R/K | Potentiometer 0,1...10 kOhm | 0...20 mA / 1...5 Vdc | 24 Vdc |
| W5MS-DA-R | Potentiometer 0,1...10 kOhm | 0...20 mA / 4...20 mA | 24 Vdc |
| W5MS-DA-R/K | Potentiometer 0,1...10 kOhm | 0...20 mA / 4...20 mA | 24 Vdc |
| W5MS-DD-R | Potentiometer 0,1...10 kOhm | 0...20 mA / 0...20 mA | 24 Vdc |
| W5MS-DD-R/K | Potentiometer 0,1...10 kOhm | 0...20 mA / 0...20 mA | 24 Vdc |
| W5PA-A1A4-R | Open Collector, 0...100 kHz | 4...20 mA / 0...10 Vdc | 24 Vdc |
| W5PA-A1A6-R | Open Collector, 0...100 kHz | 4...20 mA / 1...5 Vdc | 24 Vdc |
| W5PA-A1AA-R | Open Collector, 0...100 kHz | 4...20 mA / 4...20 mA | 24 Vdc |
| W5PA-A1AD-R | Open Collector, 0...100 kHz | 4...20 mA / 0...20 mA | 24 Vdc |
| W5PA-A2A4-R | Relay, 0...30 Hz | 4...20 mA / 0...10 Vdc | 24 Vdc |
| W5PA-A2A6-R | Relay, 0...30 Hz | 4...20 mA / 1...5 Vdc | 24 Vdc |
| W5PA-A2AA-R | Relay, 0...30 Hz | 4...20 mA / 4...20 mA | 24 Vdc |
| W5PA-A2AD-R | Relay, 0...30 Hz | 4...20 mA / 0...20 mA | 24 Vdc |
| W5PA-CA4-R | Voltage puls fix 5V, 0...100 kHz | 4...20 mA / 0...10 Vdc | 24 Vdc |
| W5PA-CA6-R | Voltage puls fix 5V, 0...100 kHz | 4...20 mA / 1...5 Vdc | 24 Vdc |
| W5PA-CAA-R | Voltage puls fix 5V, 0...100 kHz | 4...20 mA / 4...20 mA | 24 Vdc |
| W5PA-CAD-R | Voltage puls fix 5V, 0...100 kHz | 4...20 mA / 0...20 mA | 24 Vdc |
| W5PA-DA4-R | Voltage puls fix 12/24V, 0...100 kHz | 4...20 mA / 0...10 Vdc | 24 Vdc |
| W5PA-DA6-R | Voltage puls fix 12/24V, 0...100 kHz | 4...20 mA / 1...5 Vdc | 24 Vdc |
| W5PA-DAA-R | Voltage puls fix 12/24V, 0...100 kHz | 4...20 mA / 4...20 mA | 24 Vdc |
| W5PA-DAD-R | Voltage puls fix 12/24V, 0...100 kHz | 4...20 mA / 0...20 mA | 24 Vdc |
| W5RS-444-R | RTD (PT100) | 0...10 Vdc / 0...10 Vdc | 24 Vdc |
| W5RS-444-R/K | RTD (PT100) | 0...10 Vdc / 0...10 Vdc | 24 Vdc |
| W5RS-446-R | RTD (PT100) | 0...10 Vdc / 1...5 Vdc | 24 Vdc |
| W5RS-446-R/K | RTD (PT100) | 0...10 Vdc / 1...5 Vdc | 24 Vdc |
| W5RS-44A-R | RTD (PT100) | 0...10 Vdc / 4...20 mA | 24 Vdc |
| W5RS-44A-R/K | RTD (PT100) | 0...10 Vdc / 4...20 mA | 24 Vdc |
| W5RS-44D-R | RTD (PT100) | 0...10 Vdc / 0...20 mA | 24 Vdc |
| W5RS-44D-R/K | RTD (PT100) | 0...10 Vdc / 0...20 mA | 24 Vdc |
| W5RS-464-R | RTD (PT100) | 1...5 Vdc / 0...10 Vdc | 24 Vdc |
| W5RS-464-R/K | RTD (PT100) | 1...5 Vdc / 0...10 Vdc | 24 Vdc |
| W5RS-466-R | RTD (PT100) | 1...5 Vdc / 1...5 Vdc | 24 Vdc |
| W5RS-466-R/K | RTD (PT100) | 1...5 Vdc / 1...5 Vdc | 24 Vdc |
| W5RS-46A-R | RTD (PT100) | 1...5 Vdc / 4...20 mA | 24 Vdc |
| W5RS-46A-R/K | RTD (PT100) | 1...5 Vdc / 4...20 mA | 24 Vdc |
| W5RS-46D-R | RTD (PT100) | 1...5 Vdc / 0...20 mA | 24 Vdc |
| W5RS-46D-R/K | RTD (PT100) | 1...5 Vdc / 0...20 mA | 24 Vdc |
| W5RS-4A4-R | RTD (PT100) | 4...20 mA / 0...10 Vdc | 24 Vdc |
| W5RS-4A4-R/K | RTD (PT100) | 4...20 mA / 0...10 Vdc | 24 Vdc |
| W5RS-4A6-R | RTD (PT100) | 4...20 mA / 1...5 Vdc | 24 Vdc |
| W5RS-4A6-R/K | RTD (PT100) | 4...20 mA / 1...5 Vdc | 24 Vdc |
| W5RS-4AA-R | RTD (PT100) | 4...20 mA / 4...20 mA | 24 Vdc |
| W5RS-4AA-R/K | RTD (PT100) | 4...20 mA / 4...20 mA | 24 Vdc |
| W5RS-4AD-R | RTD (PT100) | 4...20 mA / 0...20 mA | 24 Vdc |
| W5RS-4AD-R/K | RTD (PT100) | 4...20 mA / 0...20 mA | 24 Vdc |
| W5RS-4D4-R | RTD (PT100) | 0...20 mA / 0...10 Vdc | 24 Vdc |
| W5RS-4D4-R/K | RTD (PT100) | 0...20 mA / 0...10 Vdc | 24 Vdc |
| W5RS-4D6-R | RTD (PT100) | 0...20 mA / 1...5 Vdc | 24 Vdc |
| W5RS-4D6-R/K | RTD (PT100) | 0...20 mA / 1...5 Vdc | 24 Vdc |
| W5RS-4DA-R | RTD (PT100) | 0...20 mA / 4...20 mA | 24 Vdc |
| W5RS-4DA-R/K | RTD (PT100) | 0...20 mA / 4...20 mA | 24 Vdc |
| W5RS-4DD-R | RTD (PT100) | 0...20 mA / 0...20 mA | 24 Vdc |
| W5RS-4DD-R/K | RTD (PT100) | 0...20 mA / 0...20 mA | 24 Vdc |
| W5TS-244-R | Thermocouple K | 0...10 Vdc / 0...10 Vdc | 24 Vdc |
| W5TS-244-R/K | Thermocouple K | 0...10 Vdc / 0...10 Vdc | 24 Vdc |
| W5TS-246-R | Thermocouple K | 0...10 Vdc / 1...5 Vdc | 24 Vdc |
| W5TS-246-R/K | Thermocouple K | 0...10 Vdc / 1...5 Vdc | 24 Vdc |
| W5TS-24A-R | Thermocouple K | 0...10 Vdc / 4...20 mA | 24 Vdc |
| W5TS-24A-R/K | Thermocouple K | 0...10 Vdc / 4...20 mA | 24 Vdc |
| W5TS-24D-R | Thermocouple K | 0...10 Vdc / 0...20 mA | 24 Vdc |
| W5TS-24D-R/K | Thermocouple K | 0...10 Vdc / 0...20 mA | 24 Vdc |
| W5TS-264-R | Thermocouple K | 1...5 Vdc / 0...10 Vdc | 24 Vdc |
| W5TS-264-R/K | Thermocouple K | 1...5 Vdc / 0...10 Vdc | 24 Vdc |
| W5TS-266-R | Thermocouple K | 1...5 Vdc / 1...5 Vdc | 24 Vdc |
| W5TS-266-R/K | Thermocouple K | 1...5 Vdc / 1...5 Vdc | 24 Vdc |
| W5TS-26A-R | Thermocouple K | 1...5 Vdc / 4...20 mA | 24 Vdc |
| W5TS-26A-R/K | Thermocouple K | 1...5 Vdc / 4...20 mA | 24 Vdc |
| W5TS-26D-R | Thermocouple K | 1...5 Vdc / 0...20 mA | 24 Vdc |
| W5TS-26D-R/K | Thermocouple K | 1...5 Vdc / 0...20 mA | 24 Vdc |
| W5TS-2A4-R | Thermocouple K | 4...20 mA / 0...10 Vdc | 24 Vdc |
| W5TS-2A4-R/K | Thermocouple K | 4...20 mA / 0...10 Vdc | 24 Vdc |
| W5TS-2A6-R | Thermocouple K | 4...20 mA / 1...5 Vdc | 24 Vdc |
| W5TS-2A6-R/K | Thermocouple K | 4...20 mA / 1...5 Vdc | 24 Vdc |
| W5TS-2AA-R | Thermocouple K | 4...20 mA / 4...20 mA | 24 Vdc |
| W5TS-2AA-R/K | Thermocouple K | 4...20 mA / 4...20 mA | 24 Vdc |
| W5TS-2AD-R | Thermocouple K | 4...20 mA / 0...20 mA | 24 Vdc |
| W5TS-2AD-R/K | Thermocouple K | 4...20 mA / 0...20 mA | 24 Vdc |
| W5TS-2D4-R | Thermocouple K | 0...20 mA / 0...10 Vdc | 24 Vdc |
| W5TS-2D4-R/K | Thermocouple K | 0...20 mA / 0...10 Vdc | 24 Vdc |
| W5TS-2D6-R | Thermocouple K | 0...20 mA / 1...5 Vdc | 24 Vdc |
| W5TS-2D6-R/K | Thermocouple K | 0...20 mA / 1...5 Vdc | 24 Vdc |
| W5TS-2DA-R | Thermocouple K | 0...20 mA / 4...20 mA | 24 Vdc |
| W5TS-2DA-R/K | Thermocouple K | 0...20 mA / 4...20 mA | 24 Vdc |
| W5TS-2DD-R | Thermocouple K | 0...20 mA / 0...20 mA | 24 Vdc |
| W5TS-2DD-R/K | Thermocouple K | 0...20 mA / 0...20 mA | 24 Vdc |
| W5VS-4A4-R | 0...10 Vdc | 4...20 mA / 0...10 Vdc | 24 Vdc |
| W5VS-4A4-R/K | 0...10 Vdc | 4...20 mA / 0...10 Vdc | 24 Vdc |
| W5VS-4A6-R | 0...10 Vdc | 4...20 mA / 1...5 Vdc | 24 Vdc |
| W5VS-4A6-R/K | 0...10 Vdc | 4...20 mA / 1...5 Vdc | 24 Vdc |
| W5VS-4AA-R | 0...10 Vdc | 4...20 mA / 4...20 mA | 24 Vdc |
| W5VS-4AA-R/K | 0...10 Vdc | 4...20 mA / 4...20 mA | 24 Vdc |
| W5VS-4AD-R | 0...10 Vdc | 4...20 mA / 0...20 mA | 24 Vdc |
| W5VS-4AD-R/K | 0...10 Vdc | 4...20 mA / 0...20 mA | 24 Vdc |
| W5VS-6A4-R | 1...5 Vdc | 4...20 mA / 0...10 Vdc | 24 Vdc |
| W5VS-6A4-R/K | 1...5 Vdc | 4...20 mA / 0...10 Vdc | 24 Vdc |
| W5VS-6A6-R | 1...5 Vdc | 4...20 mA / 1...5 Vdc | 24 Vdc |
| W5VS-6A6-R/K | 1...5 Vdc | 4...20 mA / 1...5 Vdc | 24 Vdc |
| W5VS-6AA-R | 1...5 Vdc | 4...20 mA / 4...20 mA | 24 Vdc |
| W5VS-6AA-R/K | 1...5 Vdc | 4...20 mA / 4...20 mA | 24 Vdc |
| W5VS-6AD-R | 1...5 Vdc | 4...20 mA / 0...20 mA | 24 Vdc |
| W5VS-6AD-R/K | 1...5 Vdc | 4...20 mA / 0...20 mA | 24 Vdc |
| W5VS-AA4-R | 4...20 mA | 4...20 mA / 0...10 Vdc | 24 Vdc |
| W5VS-AA4-R/K | 4...20 mA | 4...20 mA / 0...10 Vdc | 24 Vdc |
| W5VS-AA6-R | 4...20 mA | 4...20 mA / 1...5 Vdc | 24 Vdc |
| W5VS-AA6-R/K | 4...20 mA | 4...20 mA / 1...5 Vdc | 24 Vdc |
| W5VS-AAA-R | 4...20 mA | 4...20 mA / 4...20 mA | 24 Vdc |
| W5VS-AAA-R/K | 4...20 mA | 4...20 mA / 4...20 mA | 24 Vdc |
| W5VS-AAD-R | 4...20 mA | 4...20 mA / 0...20 mA | 24 Vdc |
| W5VS-AAD-R/K | 4...20 mA | 4...20 mA / 0...20 mA | 24 Vdc |
| W5VS-DA4-R | 0...20 mA | 4...20 mA / 0...10 Vdc | 24 Vdc |
| W5VS-DA4-R/K | 0...20 mA | 4...20 mA / 0...10 Vdc | 24 Vdc |
| W5VS-DA6-R | 0...20 mA | 4...20 mA / 1...5 Vdc | 24 Vdc |
| W5VS-DA6-R/K | 0...20 mA | 4...20 mA / 1...5 Vdc | 24 Vdc |
| W5VS-DAA-R | 0...20 mA | 4...20 mA / 4...20 mA | 24 Vdc |
| W5VS-DAD-R | 0...20 mA | 4...20 mA / 0...20 mA | 24 Vdc |
| W5VS-DAD-R/K | 0...20 mA | 4...20 mA / 0...20 mA | 24 Vdc |






