MDA-TL LIGHTNING SURGE PROTECTOR FOR ANALOG TELECOM LINE USE

Liên hệ Còn hàng

MDA-TL

Lightning Surge Protectors for
Electronics Equipment M-RESTER

LIGHTNING SURGE PROTECTOR FOR
ANALOG TELECOM LINE USE

(life monitor)
Functions & Features
• Designed specifically to protect telecommunication equipment from lightning surges entering through telecommunication line network
• Absorbing surges only without affecting instrumentation signal
• Life monitor function helps you to decide when you should replace the M-RESTER; reduces maintenance and prevents downtime
• LED display and alarm contact output indicate the degradation and life span of the surge protection circuits

MODEL: MDA–TL–[1]

ORDERING INFORMATION

• Code number: MDA-TL-[1]
Specify a code from below for [1].
  (e.g. MDA-TL-M)

[1] POWER INPUT

AC Power
M: 85 – 264 V AC (Operational voltage range 85 – 264 V,
47 – 66 Hz)
DC Power
R2: 11 – 27 V DC
(Operational voltage range 11 – 27 V, ripple 10 %p-p max.)
P: 110 V DC
(Operational voltage range 85 – 150 V, ripple 10 %p-p max.)

GENERAL SPECIFICATIONS

Construction: Plug-in
Connection
  Telecom line: Modular jack or M3.5 screw terminals
  (torque 0.8 N·m);
  Line screw terminal connection must be handled by
  qualified personnel.
  Ground: M3.5 screw terminals (torque 0.8 N·m)
Modular jack cord: 6-pole, 2-core
Screw terminal: Nickel-plated steel
Housing material: Flame-resistant resin (black)
Alarm indicators
  Power: The green LED turns on while the power is supplied.
  Alarm: Tricolor LED (green/amber/red)
  •Remains off when the power supply is first turned on.
  •Green: The unit has received one or more surges.
  •Amber: Replacement is recommended.
  •Red: The life span has ended.
  Life time judged: When the number of discharges
  of the discharge element reaches the expected life span.
Alarm contact: The N.C. contact is on when the life span of the discharge elements has ended and/or when the power supply is removed.
  Rating: 125 V AC @ 0.5 A (cos ø = 1)
  30 V DC @ 1 A (resistive load)
  Maximum switching voltage: 125 V AC or 110 V DC
  Maximum switching power: 62.5 VA or 30 W
  Minimum load: 5 V DC @ 1 mA

INSTALLATION

Power consumption
•AC: Approx. 2 VA at 100 V
 Approx. 3 VA at 200 V
 Approx. 4 VA at 240 V
•DC: Approx. 1.5 W
Operating temperature: -5 to +55°C (23 to 131°F)
Operating humidity: 30 to 90 %RH (non-condensing)
Mounting: Surface or DIN rail; Standard Rack Mounting Frame BX-16H available
Weight: 150 g (0.33 lb)

PERFORMANCE

Discharge voltage (peak voltage)
  Line to line: ±190 V min.
  Line to ground: ±180 V min.
Maximum surge voltage
  Line to line: ±500 V max.
  Line to ground: ±900 V max.
(The maximum voltage that could pass through M-RESTER. Protected equipment must be able to withstand this voltage for very short time period.)
Response time: ≤ 0.01 μsec.
Leakage current:
  Line to line: ≤ 100 μA @ ±160 V DC
  Line to ground: ≤ 100 μA @ ±160 V DC
Discharge current capacity
  Modular jack connection: 500 A (8 / 20 μsec.)
  Screw terminal connection: 10000 A (8 / 20 μsec.)
Maximum load current: 200 mA
Insulation resistance: ≥ 100 MΩ with 500 V DC
(surge protector circuit to alarm output to power)
Dielectric strength: 2000 V AC @ 1 minute (surge protector circuit to power to alarm output to ground)
Internal series resistance: Approx. 4 Ω including return
Maximum line voltage: ±160 V DC
Frequency band: Approx. 100 kHz/-3 dB at 600 Ω terminating resistance

EXTERNAL VIEW

GROUNDING

EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm [inch]

SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM

--------------------

CÔNG TY CỔ PHẦN KỸ THUẬT VÀ THƯƠNG MẠI THIẾT BỊ CÔNG NGHIỆP NTD

Adress: No. 28, Alley 36 Co Linh Street, Group 7, Long Bien Ward, Long Bien District, Hanoi City, Vietnam.

Hotline: 0971961212

Mail: sales@ntd-automation.com

 