MSP4C2 MINI-TOP ELECTRONIC ACTUATOR

Liên hệ Còn hàng

MSP4C2

Final Control Elements

MINI-TOP ELECTRONIC ACTUATOR

(linear type; CC-Link)
Functions & Features
• Small-size control valve actuator
• Direct connection to CC-Link capable PLC and other devices on the same network
• Easy wired
• Uploading device information via CC-Link for maintenance purpose
• 1/1000 high resolution
• Easy adjustment: electronic limiter at the valve open & closed positions
• Overload protection
• Seal-spring incorporated for pressing direction
Typical Applications
• For CP control valve in paper manufacturing
• Fuel mixing control for combustion control system
• Air conditioning for buildings and factories
 

MODEL: MSP4C2–[1][2][3]–0R

ORDERING INFORMATION

• Code number: MSP4C2-[1][2][3]-0R
Specify a code from below for each of [1] through [3].
  (e.g. MSP4C2-271-0R)

[1] STROKE

1: 5 to 10 mm (.20” to .39”)
2: 8 to 15 mm (.31” to .59”)

[2] OPERATION TIME, THRUST

3: 5 sec. / 10 mm, 150 N
4: 9 sec. / 10 mm, 300 N
7: 18 sec. / 10 mm, 700 N

[3] OUTPUT STEM TYPE

6: M6 female thread, 0.75 pitch
8: M8 female thread, 1.0 pitch
1: M10 female thread, 1.25 pitch
D: M6 female thread, 1.0 pitch
E: M8 female thread, 1.25 pitch
F: M10 female thread, 1.5 pitch

CE MARKING

0: Without

POWER INPUT

DC Power
R: 24 V DC
(Operational voltage range 24 V ±10 %, ripple 10 %p-p max.)

PACKAGE INCLUDES...

• Terminating resistor (110 Ω, 0.5 W)

GENERAL SPECIFICATIONS

Degree of protection: IP66
Operation at a communication error: Extend, retract or stop
Electrical connection: M3 screw terminals (torque 0.8 N·m)
Screw terminal: Nickel-plated steel
Transmission cable: Conforms to CC-Link Ver 1.10
Housing material: Diecast aluminum
(Cast aluminum for the terminal box;  steel for the cover)
Drive: Stepping motor
Insulation class: E
Position detection: Potentiometer
Deadband: 0.1 – 1.9 % adjustable (factory set to 1.5 %)
Restarting timer: 0 – 10 sec. adjustable
(factory set to 1.5 sec.)
Isolation: Housing or FE1 to communication to power
Zero adjustment: 0 – 25 %
Span adjustment: 50 - 100 %
Protective functions: Overload protection
Status indicator LED: Red light blinks in 2 sec. intervals in normal operations; blinks in 0.5 sec. intervals when a foreign object is detected mechanically caught inside.
Manual operating handle: Not available

CC-Link COMMUNICATION

Protocol: CC-Link V1.10
Device type: Remote device station
Station No. setting: Rotary switch; 1 – 64
Required node: 1
Baud rate setting: Rotary switch
L RUN indicator: Red LED
L ERR. indicator: Red LED

INSTALLATION

Current consumption
•DC: Approx. 0.5 A
Operating temperature: -5 to +55°C (23 to 131°F)
Operating humidity: 30 to 85 %RH (non-condensing)
Vibration: 0.5 G (4.9 m/s2) max.
Mounting position: All directions 
Do not mount the actuator with its output stem or wiring conduit on the upside if the actuator is to be exposed to dripping water.
Weight: 1.8 kg (4.0 lb)

PERFORMANCE

Resolution: 1/1000 or 0.015 mm, whichever is greater, with 0.1 % deadband setting
Insulation resistance: ≥ 100 MΩ with 100 V DC
Dielectric strength: 100 V AC @ 1 minute
(housing or FE1 to communication to power)

COMMUNICATIONS

EXTERNAL DIMENSIONS unit: mm [inch]

SCHEMATIC CIRCUITRY

--------------------

CÔNG TY CỔ PHẦN KỸ THUẬT VÀ THƯƠNG MẠI THIẾT BỊ CÔNG NGHIỆP NTD

Adress: No. 28, Alley 36 Co Linh Street, Group 7, Long Bien Ward, Long Bien District, Hanoi City, Vietnam.

Hotline: 0971961212

Mail: sales@ntd-automation.com

Tags: