![Accessories](http://bizweb.dktcdn.net/100/332/095/products/ntd-phan-phoi-chinh-hang-89.png?v=1603168724283)
Accessories
Honeywell Kromschröder là một trong các nhà sản xuất nổi tiếng về lò công nghiệp. Luôn đem đến sự an toàn, giá cả phải chăng và có độ tin cậy cao cho doanh nghiệp.
Accessories bao gồm:
+ Visual discharge unit AS
+ Flow meters DM, DE
+ Stainless steel bellows units EKO
+ Stainless steel flexible tubes ES
+ Non-return gas valves GRS, GRSF
+ Manometer KFM, RFM
+ Adjusting cocks GEHV, GEH, LEH
+ Orifice assemblies FLS
Trong đó:
Visual discharge unit AS
Visual discharge unit for the monitoring of gas valves for tightness used in conjunction with the solenoid relief valve VAN (Bộ xả trực quan để giám sát độ kín của van khí được sử dụng cùng với van xả điện từ VAN).
Flow meters DM, DE
Turbine wheel meters for measuring gas flow on gas consumption equipment, for gas burner adjustment, for gas and air.
DM: mechanical counter head,
DE: electronic counter head,
measuring range: 1.6 to 1600 m3/h,
DN: 25 to 150,
connection: thread or installation between two flanges,
pe: max. 4 bar,
M bus interface for DE available.
Stainless steel bellows units EKO
Stainless steel bellows units for stress-free pipe installation and for avoiding transmission of vibrations, for gas, air and water, with restricting orifice if required, DIN-DVGW tested and registered.
DN: 15 to 200,
connection: internal thread, external thread or flange,
pe: max. 4 or 10 bar.
Stainless steel flexible tubes ES
Stainless steel flexible tubes for stress-free, flexible connection of devices and pipes and to avoid transmission of vibrations, for gas, air and water, DIN-DVGW tested and registered.
DN: 8 to 100,
connection: external thread,
pe: max. 4 or 16 bar,
length: 500 to 2000 mm.
Non-return gas valves GRS, GRSF
Non-return gas valve to prevent gas creepage or surge, for gas, air and oxygen, DIN-DVGW tested and registered.
GRS: not flame-arresting,
GRSF: with sinter bronze flame arrester, so flame-arresting in the case of use with combustion air,
DN: 15 to 80,
connection: thread or flange,
pe: max. 100 mbar or 5 bar.
Manometer KFM, RFM
Pressure gauges with capsule elements and Bourdon tubes for pressure display, resistant to positive pressure, with zero point correction, for gas and air.
Measuring ranges:
KFM: 0 to 400 mbar,
RFM: 0 to 16 bar,
diameter: 63 or 100 mm.
Adjusting cocks GEHV, GEH, LEH
Adjusting cocks for precise adjustment of flow rates.
GEHV: for gas pe max. 1 bar,
for air pe max. 4 bar,
operated by hand wheel with adjusting scale, DIN-DVGW tested and registered.
GEH: for gas, pe max. 1 bar, tool-operated.
LEH: for air, pe max. 4 bar,
operated by hand wheel.
DN: 8 to 50,
connection: internal thread on both ends or internal/external thread.
Orifice assemblies FLS
The appropiate differential pressure can be checked using two pressure test points before and after the orifice.
NTD là nhà phân phối HONEYWELL VIET NAM Distributor | HONEYWELL VIETNAM / KROMSCHRÖDER VIETNAM / HONEYWELL VIETNAM CHÍNH HÃNG.
------------------------
CÔNG TY CỐ PHẦN KỸ THUẬT VÀ THƯƠNG MẠI THIẾT BỊ CÔNG NGHIỆP NTD
VPGD: Số 9, Ngõ 651/82/3 Minh Khai, Hai Bà Trưng, Hà Nội.
Hotline: 0971961212
Mail: sales@ntd-automation.com