SD10 3-input channels, Bargraph, 4-digit Digital Display, Alarm Output
SD10 Single Loop Controller Series
BARGRAPH INDICATING ALARM
(with 4-digit digital meter, LED bar indicator)
Functions & Features
• Panel designed to match the SC series controllers.
• Displays a process variable in graphic bargraph of 101 LED segments
• 3 input channels
• Clear 4-digit digital meter
• Provides max. 4 alarm contact outputs
• LED brightness adjustments
• IP55 front cover
• Multi-color indicator (red, orange and green)
• Scale plate is easily replaceable
Typical Applications
• Panel operation for small-scale instrumentation
• Various alarm applications
MODEL: SD10-[1][2][3][4][5][6][7][8][9]-[10]
ORDERING INFORMATION
• Code number: SD10-[1][2][3][4][5][6][7][8][9]-[10]
Specify a code from below for each [1] through [10].
(e.g. SD10-RYGAA0A6Y-M2)
• Use Ordering Information Sheet (No. ESU-6341) for the I/O codes, digital display range, decimal point position and alarm setpoint.
• Bargraph range (Refer to 'SCALE PLATE')
[1] BAR LED COLOR (INPUT 1)
R: Red
Y: Amber
G: Green
B: Blue
1: Multi-color (red, orange and green), (See ‘External View.’)
[2] BAR LED COLOR (INPUT 2)
Same color availability as Input 1
[3] BAR LED COLOR (INPUT 3)
Same color availability as Input 1
[4] INPUT 1
Current
A: 4 – 20 mA DC (Input resistance 10 Ω)
Z: Specify current (See INPUT SPECIFICATIONS)
Voltage
6: 1 – 5 V DC (Input resistance 1 MΩ min.)
0: Specify voltage (See INPUT SPECIFICATIONS)
[5] INPUT 2
Same range availability as Input 1
[6] INPUT 3
Same range availability as Input 1
[7] DC OUTPUT 1
Y: Without
Current
A: 4 – 20 mA DC (Load resistance 550 Ω max.)
D: 0 – 20 mA DC (Load resistance 550 Ω max.)
Voltage
6: 1 – 5 V DC (Load resistance 10 kΩ min.)
0: Specify voltage (See OUTPUT SPECIFICATIONS)
[8] DC OUTPUT 2
Same range availability as DC Output 1
[9] DC OUTPUT 3
Same range availability as DC Output 1
[10] POWER INPUT
AC Power
M2: 100 – 240 V AC (Operational voltage range 85 – 264 V,
47 – 66 Hz)
DC Power
R: 24 V DC
(Operational voltage range 24 V ±10 %, ripple 10 %p-p max.)
48NDT-41V2-R/CE Thermocouple K 4x Contacts
48NDT-42V2-R/CE Thermocouple K 4x Contacts
48NDT-41V4-R/CE Thermocouple J 4x Contacts
48NDT-42V4-R/CE Thermocouple J 4x Contacts
48NDR-41V4-R/CE RTD (PT50, PT100, Ni) 4x Contacts
48NDR-42V4-R/CE RTD (PT50, PT100, Ni) 4x Contacts
48NDM-41V-R/CE Potentiometer 0,1...10 kOhm 4x Contacts
48NDM-42V-R/CE Potentiometer 0,1...10 kOhm 4x Contacts
48NDV-4C1VA-R/CE 4...20 mA 4x Contacts
48NDV-4C1VD-R/CE 0...20 mA 4x Contacts
48NDV-4C1V4-R/CE 0...10 Vdc 4x Contacts
48NDV-4C1V6-R/CE 1...5 Vdc 4x Contacts
48NDV-4C2VA-R/CE 4...20 mA 4x Contacts
48NDV-4C2VD-R/CE 0...20 mA 4x Contacts
48NDV-4C2V4-R/CE 0...10 Vdc 4x Contacts
48NDV-4C2V6-R/CE 1...5 Vdc 4x Contacts
48NDT-4RV2-R/CE Thermocouple K 4x Contacts
48NDT-4YV2-R/CE Thermocouple K 4x Contacts
48NDT-4GV2-R/CE Thermocouple K 4x Contacts
48NDT-4RV4-R/CE Thermocouple J 4x Contacts
48NDT-4YV4-R/CE Thermocouple J 4x Contacts
48NDT-4GV4-R/CE Thermocouple J 4x Contacts
48NDR-4RV4-R/CE RTD (PT50, PT100, Ni) 4x Contacts
48NDR-4YV4-R/CE RTD (PT50, PT100, Ni) 4x Contacts
48NDR-4GV4-R/CE RTD (PT50, PT100, Ni) 4x Contacts
48NDM-4RV-R/CE Potentiometer 0,1...10 kOhm 4x Contacts
48NDM-4YV-R/CE Potentiometer 0,1...10 kOhm 4x Contacts
48NDM-4GV-R/CE Potentiometer 0,1...10 kOhm 4x Contacts
48NDV-4RVA-R/CE 4...20 mA 4x Contacts
48NDV-4RVD-R/CE 0...20 mA 4x Contacts
48NDV-4RV4-R/CE 0...10 Vdc 4x Contacts
48NDV-4RV6-R/CE 1...5 Vdc 4x Contacts
48NDV-4YVA-R/CE 4...20 mA 4x Contacts
48NDV-4YVD-R/CE 0...20 mA 4x Contacts
48NDV-4YV4-R/CE 0...10 Vdc 4x Contacts
48NDV-4YV6-R/CE 1...5 Vdc 4x Contacts
48NDV-4GVA-R/CE 4...20 mA 4x Contacts
48NDV-4GVD-R/CE 0...20 mA 4x Contacts
48NDV-4GV4-R/CE 0...10 Vdc 4x Contacts
48NDV-4GV6-R/CE 1...5 Vdc 4x Contacts
48NAT-41V2-R/CE Thermocouple K 4x Contacts
48NAT-42V2-R/CE Thermocouple K 4x Contacts
48NAT-41V4-R/CE Thermocouple J 4x Contacts
48NAT-42V4-R/CE Thermocouple J 4x Contacts
48NAT-41H2-R/CE Thermocouple K 4x Contacts
48NAT-42H2-R/CE Thermocouple K 4x Contacts
48NAT-41H4-R/CE Thermocouple J 4x Contacts
48NAT-42H4-R/CE Thermocouple J 4x Contacts
48NAR-41V4-R/CE RTD (PT50, PT100, Ni) 4x Contacts
48NAR-42V4-R/CE RTD (PT50, PT100, Ni) 4x Contacts
48NAR-41H4-R/CE RTD (PT50, PT100, Ni) 4x Contacts
48NAR-42H4-R/CE RTD (PT50, PT100, Ni) 4x Contacts
48NAM-41V-R/CE Potentiometer 0,1...10 kOhm 4x Contacts
48NAM-42V-R/CE Potentiometer 0,1...10 kOhm 4x Contacts
48NAM-41H-R/CE Potentiometer 0,1...10 kOhm 4x Contacts
48NAM-42H-R/CE Potentiometer 0,1...10 kOhm 4x Contacts
48NDT-21V2-R/CE Thermocouple K 2x changeover relay
48NDT-22V2-R/CE Thermocouple K 2x changeover relay
48NDT-21V4-R/CE Thermocouple J 2x changeover relay
48NDT-22V4-R/CE Thermocouple J 2x changeover relay
48NDR-21V4-R/CE RTD (PT50, PT100, Ni) 2x changeover relay
48NDR-22V4-R/CE RTD (PT50, PT100, Ni) 2x changeover relay
48NDM-21V-R/CE Potentiometer 0,1...10 kOhm 2x changeover relay
48NDM-22V-R/CE Potentiometer 0,1...10 kOhm 2x changeover relay
48NAV-4C1VA-R/CE 4...20 mA 4x Contacts






