Sensors for valve actuators
Sensors for valve actuators
-
Quick and secure mounting with only three screws
- Units with M12 connector or terminal chamber
- Non-contact and self-cleaning system
- High shock and vibration resistance
- Large selection of switching cams
Position sensor for valve actuators MVQ101
Position sensor for valve actuators MVQ201
Inductive dual sensor for valve actuators IN5225
Inductive dual sensor for valve actuators IN5327
Inductive dual sensor for valve actuators IN5224
Inductive sensor IN5409
Inductive sensor IN5417
Inductive dual sensor for valve actuators IN5415
AS-Interface dual sensor for pneumatic valve actuators AC2310
Inductive dual sensor for valve actuators IN5337
Inductive dual sensor for valve actuators IN507A
Inductive sensor IN5410
Inductive NAMUR dual sensor for valve actuators NN5008
Inductive dual sensor for valve actuators IN0110
Inductive sensor NN505A
AS-Interface dual sensor for pneumatic valve actuators AC336A
Inductive dual sensor for valve actuators IN0109
Inductive sensor NN506A
Inductive dual sensor for valve actuators IN5416
Inductive sensor IN0131
AS-Interface dual sensor for pneumatic valve actuators AC2317
Inductive dual sensor for valve actuators IN5304
Inductive dual sensor for valve actuators IN0126
AS-Interface dual sensor for pneumatic valve actuators AC326A
Inductive dual sensor for valve actuators IN5323
Inductive dual sensor for valve actuators IN0118
Inductive dual sensor for valve actuators IN5424
Inductive dual sensor for valve actuators IN0137
Inductive dual sensor for valve actuators IN0137
Inductive dual sensor for valve actuators IN5377
Inductive NAMUR dual sensor for valve actuators NN5011
Inductive dual sensor for valve actuators IN5345
Inductive dual sensor for valve actuators IN5460
Dual inductive sensors for valve actuators
In industrial processes where liquids, air or gases are used, valves are needed for dosing and control. Dual inductive sensors of the IN and AC23 series provide reliable feedback of the valve positions on pneumatic valve actuators and valves. They are operated in combination with a switch target (also called 'puck').
The puck is mounted directly on the actuator shaft. It is equipped with two metal screws that are mounted at different heights and offset by 90°. A dual inductive sensor with two integral sensors detects the upper or the lower metal screw and, thus, the "open" or "closed" position of the valve. The system operates without contact or wear and is self-cleaning. It is virtually resistant to external influence and insensitive to mechanical stress such as vibration and shock.
The dual sensor is available with two switching outputs or AS-Interface.
-------------------------------------