Use in welding applications
Use in welding applications
-
Magnetic-field immune
- Long sensing range for high uptime
- Large variety of different types
- Cylindrical types with high switching frequency
- Resistant to weld slag thanks to non-stick coating
Inductive full-metal sensor IFR212
Inductive full-metal sensor IGR212
Inductive full-metal sensor IIR212
Inductive sensor IQW200
Inductive sensor IQW201
Inductive full-metal sensor IFR200
Inductive sensor IGW202
Inductive sensor IGW205
Inductive full-metal sensor IFR203
Inductive sensor IFW204
Inductive sensor IFW210
Inductive sensor IFW211
Inductive full-metal sensor IGR200
Inductive full-metal sensor IFR204
Inductive full-metal sensor IGR203
Inductive sensor IIW202
Inductive sensor IIW204
Inductive sensor IM5126
Inductive full-metal sensor IGR206
Inductive sensor IM5124
Inductive full-metal sensor IGR204
Inductive full-metal sensor IFR206
Inductive sensor IM5119
Inductive sensor IEW200
Inductive sensor IEW205
Inductive sensor IEW206
Inductive sensor IEW207
Inductive sensor IM5129
Inductive full-metal sensor IGR205
Inductive full-metal sensor IIR203
Inductive full-metal sensor IIR200
Inductive sensor IEW201
Inductive full-metal sensor IFR207
Inductive full-metal sensor IIR206
Inductive full-metal sensor IGR207
Inductive full-metal sensor IIR205
Inductive full-metal sensor IFR202
Inductive full-metal sensor IFR205
Inductive full-metal sensor IIR204
Inductive sensor IFW200
Inductive full-metal sensor IGR202
Inductive sensor IM5120
Inductive full-metal sensor IIR202
Inductive sensor IM5125
Inductive sensor IGW200
Inductive sensor IGW201
Inductive sensor IFW201
Inductive sensor IF5750
Inductive sensor IG5667
Inductive sensor IF5675
Inductive sensor IF5670
Inductive sensor IG5647
Inductive sensor IF5751
Inductive sensor II5503
Inductive sensor II5711
Inductive full-metal sensor IIR207
Inductive sensor IIW200
Inductive sensor IIW201
Use in welding applications
Electromagnetic interference produced during resistance welding can easily throw inductive sensors off balance. The inductive electromagnetic field immune sensors of the W series are protected against this by a special coil structure. In AC/DC and medium-frequency welding systems these sensors guarantee high operational reliability and plant uptime.
The non-stick coating allows weld spatter to roll off the sensor and enables easy and quick cleaning. The sensing faces of the sensors consist of resistant Duroplast. The metal sleeves are PTFE-coated in addition.
The sensors have the same sensing range on all metals thanks to a correction factor of K = 1.
The protection rating IP 69K provides reliable protection against ingress of dust and moisture.
In combination with the connectors of the ecolink EVW series, the inductive sensors of the W series are the perfect choice for welding applications.
The threaded body and the sensing face of the full-metal sensors of the R series are made of high-grade stainless steel. This makes them mechanically resistant to impacts at the sensing face.
-------------------------------------
CÔNG TY CỔ PHẦN KỸ THUẬT VÀ THƯƠNG MẠI THIẾT BỊ CÔNG NGHIỆP NTD
VPGD: Số 9, Ngõ 651/82/3 Minh Khai, Hai Bà Trưng, Hà Nội.
Hotline: 0971961212
Mail: sales@ntd-automation.com






