Van giảm áp chéo trực tiếp - Dòng DXV
Van Parker DXV Crossover Relief bảo vệ quá tải áp suất cho bộ truyền động với lưu lượng xả dưới 10 GPM.
| Products | Pressure Relief Setting (psi) | Kích cỡ cổng | Adjustment Type |
|---|---|---|---|
| DXV-8-400 | 50-400 | SAE-8 | Shim Adjustable |
| DXV-8-750 | 400-750 | SAE-8 | Shim Adjustable |
| DXV-8-900 | 750-900 | SAE-8 | Shim Adjustable |
| DXV-8-1300 | 900-1300 | SAE-8 | Shim Adjustable |
| DXV-8-1450 | 1300-1450 | SAE-8 | Shim Adjustable |
| DXV-8-1800 | 1450-1800 | SAE-8 | Shim Adjustable |
| DXV-8-2000 | 1800-2000 | SAE-8 | Shim Adjustable |
| DXV-8-3000 | 2000-3000 | SAE-8 | Shim Adjustable |
| DXV-10-400 | 50-400 | SAE-10 | Shim Adjustable |
| DXV-10-750 | 400-750 | SAE-10 | Shim Adjustable |
| DXV-10-900 | 750-900 | SAE-10 | Shim Adjustable |
| DXV-10-1300 | 900-1300 | SAE-10 | Shim Adjustable |
| DXV-10-1450 | 1300-1450 | SAE-10 | Shim Adjustable |
| DXV-10-1800 | 1450-1800 | SAE-10 | Shim Adjustable |
| DXV-10-2000 | 1800-2000 | SAE-10 | Shim Adjustable |
| DXV-10-3000 | 2000-3000 | SAE-10 | Shim Adjustable |
| DXV-38-400 | 50-400 | 3/8" NPT | Shim Adjustable |
| DXV-38-750 | 400-750 | 3/8" NPT | Shim Adjustable |
| DXV-38-900 | 750-900 | 3/8" NPT | Shim Adjustable |
| DXV-38-1300 | 900-1300 | 3/8" NPT | Shim Adjustable |
| DXV-38-1450 | 1300-1450 | 3/8" NPT | Shim Adjustable |
| DXV-38-1800 | 1450-1800 | 3/8" NPT | Shim Adjustable |
| DXV-38-2000 | 1800-2000 | 3/8" NPT | Shim Adjustable |
| DXV-50-400 | 50-400 | 1/2" NPT | Shim Adjustable |
| DXV-50-750 | 400-750 | 1/2" NPT | Shim Adjustable |
| DXV-50-900 | 750-900 | 1/2" NPT | Shim Adjustable |
| DXV-50-1300 | 900-1300 | 1/2" NPT | Shim Adjustable |
| DXV-50-1450 | 1300-1450 | 1/2" NPT | Shim Adjustable |
| DXV-50-1800 | 1450-1800 | 1/2" NPT | Shim Adjustable |
| DXV-50-2000 | 1800-2000 | 1/2" NPT | Shim Adjustable |
| DXV-75-400 | 50-400 | 3/4" NPT | Shim Adjustable |
| DXV-75-750 | 400-750 | 3/4" NPT | Shim Adjustable |
| DXV-75-900 | 750-900 | 3/4" NPT | Shim Adjustable |
| DXV-75-1300 | 900-1300 | 3/4" NPT | Shim Adjustable |
| DXV-75-1450 | 1300-1450 | 3/4" NPT | Shim Adjustable |
| DXV-75-1800 | 1450-1800 | 3/4" NPT | Shim Adjustable |
| DXV-75-2000 | 1800-2000 | 3/4" NPT | Shim Adjustable |
------------------------
Nhà phân phối sản phẩm Parker tại Việt Nam - Parker Vietnam Distributor
CÔNG TY CỔ PHẦN KỸ THUẬT VÀ THƯƠNG MẠI THIẾT BỊ CÔNG NGHIỆP NTD
Adress: No. 28, Alley 36 Co Linh Street, Group 7, Long Bien Ward, Long Bien District, Hanoi City, Vietnam.
Hotline: 0971961212
Mail: sales@ntd-automation.com