M3LR - RTD input, PC & "One-Step Cal" programmable
M3LR - Space-saving Signal Conditioners M3-UNIT Series
RTD TRANSMITTER
(field- and PC-configurable)
Functions & Features
• Accepts an RTD input and provides an isolated, linearized DC signal
• Easy ‘One-Step Cal’ calibration using the front three control buttons without needing a PC; PC software is also usable.
• Both input and output type and range are configurable
• Front control button function can be locked
• Linearization and burnout
MODEL: M3LR–R4/[1][2]
ORDERING INFORMATION
• Code number: M3LR-R4/[1][2]
Specify a code from below for each [1] and [2].
(e.g. M3LR-R4/A/UL/Q)
• Specify the specification for option code /Q
(e.g. /C01)
• Orders will be shipped with default factory settings (3-wire Pt 100, 0 – 100°C input/4 – 20 mA output).
INPUT – Field-selectable
RTD
Pt 100, Pt 200, Pt 300, Pt 400, Pt 500, Pt 1000,
Ni 100, Ni 120, Ni 508.4Ω, Ni-Fe 604,
Cu 10 @25°C, Pt 50Ω, JPt 100
OUTPUT – Field-selectable
Current
0 – 20 mA DC
Voltage
-2.5 – +2.5 V DC
-10 – +10 V DC
POWER INPUT
DC Power
R4: 10 – 32 V DC
(Operational voltage range 9 - 36 V, ripple 10 %p-p max.)
[1] CONFIGURATION OPTIONS
A: PC and field configurable
B: Field configurable
[2] OPTIONS (multiple selections)
Standards & Approvals
blank: CE marking
/UL: UL approval, CE marking
Other Options
blank: none
/Q: Option other than the above (specify the specification)
SPECIFICATIONS OF OPTION: Q
COATING (For the detail, refer to M-System's web site.)
/C01: Silicone coating
/C02: Polyurethane coating
/C03: Rubber coating (UL not available)
RELATED PRODUCTS
• PC configurator software (model: M3CFG)
Downloadable at M-System’s web site.
A dedicated cable is required to connect the module to the PC. Please refer to the internet software download site or the users manual for the PC configurator for applicable cable types.
GENERAL SPECIFICATIONS
Construction: Small-sized front terminal structure
Connection: Euro type connector terminal
(applicable wire size: 0.2 to 2.5 mm2, stripped length: 8 mm)
Housing material: Flame-resistant resin (gray)
Isolation: Input to output to power
Overrange output: -15 to +115 %
Zero adjustment: -15 to +15 % (front)
Span adjustment: 85 to 115 % (front)
Burnout: Upscale (default), downscale or no burnout selectable
Linearization: Standard
Status indicator LED: Tri-color (green/amber/red) LED; Blinking patterns indicate operation status of the transmitter.
Configuration:
PC Configurator: (Model: M3LVCFG) via Windows PC connected to th front jack.
Programmable features include:
• I/O type, number of wires and range
• Zero and span adjustments
• Burnout action
• User’s RTD table setting
(max. 300 points, input resistance specified
within 0 – 30 kΩ)
(Refer to the instruction manual)
‘One-Step Cal’ calibration: With I/O type and the full-scale range configured via the internal DIP switches, precise 0 % and 100 % ranges are calibrated via the front control buttons with a help of LED. Also I/O calibration and fine adjustment are available with a PC.
Configurator connection: 2.5 dia. miniature jack;
RS-232-C level
INPUT SPECIFICATIONS
■ RTD: See Table 1.
Number of wires: 2, 3 or 4 wires
Excitation: ≤ 1.0 mA
Allowable leadwire resistance: 20 Ω per wire
Temperature range: See Table 1.
OUTPUT SPECIFICATIONS
■ DC Current
Maximum range: 0 – 20 mA DC
Minimum span: 1 mA
Conformance range: 0 – 24 mA DC
(Negative overrange current below 0 mA is not available.)
Offset: Lower range can be any specific value within the output range provided that the minimum span is maintained.
Load resistance: Output drive 12 V maximum
■ DC Voltage
Narrow Spans
Maximum range: -2.5 – +2.5 V DC
Minimum span: 250 mV
Conformance range: -3 – +3 V DC
Wide Spans
Maximum range: -10 – +10 V DC
Minimum span: 1 V
Conformance range: -11.5 – +11.5 V DC
Offset: Lower range can be any specific value within the output range provided that the minimum span is maintained.
Load resistance: Output drive 1 mA maximum
INSTALLATION
Power consumption
•DC: Approx. 3 W
Operating temperature: -25 to +65°C (-13 to +149°F)
Max. 55°C (131°F) for UL approval
Operating humidity: 0 to 95 %RH (non-condensing)
Mounting: DIN rail
Weight: 100 g (3.53 oz)
PERFORMANCE
Accuracy: See Table 1 and refer to calculation examples of overall accuracy.
Temp. coefficient: ±0.015 %/°C (±0.008 %/°F) of max. range at -5 to +55°C (23 to 131°F)
Response time: ≤ 0.9 sec. (0 – 90 %)
Burnout response: ≤ 10 sec.
Line voltage effect: ±0.1 % over voltage range
Insulation resistance: ≥ 100 MΩ with 500 V DC
Dielectric strength: 1500 V AC @ 1 minute
(input to output or power to ground)
500 V AC @ 1 minute (output to power)
CALCULATION EXAMPLES OF OVERALL ACCURACY
■ CALCULATION EXAMPLES OF OVERALL ACCURACY IN %
1) Pt 100, 0 – 500°C, 4 – 20 mA DC output
Absolute value accuracy (Table 1): 0.15°C
0.15°C ÷ 500°C × 100 = 0.03 % < 0.1%
Output span 16 mA (20 – 4) ≥ 2 mA (max. span 20 mA × 0.1) ➠ No adding 0.2 %
➠ Overall accuracy = ±0.1 % of span
2) Pt 100, 0 – 100°C, 2.0 – 2.5 V DC output